37
ProfiTech M
OPERATING MANUAL
VERSION 07/2014
ORDER NUMBER DOC 2335144
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be lower than
30 °C; 86 °F.
Volume measures:
for volumes specifi ed in Nm³ (standard cubic meters). One cubic meter of a gas at 0 °C and
1.013 bar is called norm cubic meter.
HINT
Compressed air quality, accessories
Danger of damage to the device.
Operate the control unit only with the prescribed compressed air quality.
Only use the control unit with original Wagner accessories.
Non-observance of these conditions results in the warranty expiring!
Outgoing air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water
(Quality Standard 3.5.2 according to ISO 8573.1)
3.5.2 = 5 μm / +7 °C; 44.6 °F / 0.1 mg/m³.
WARNING
6.13
COMPRESSED AIR QUALITY