5. Pressure regulator unit
22
Switch box with electronic pressure regulator unit
23
Pressure regulator
EP 3000 230 V
24
Motor safety switch
EP 3000 400 V
25
Motor safety switch
The required operating pressure is adjusted (infinitely
variable) using the pressure regulator.
Turn right as far as possible – maximum operating
pressure.
Turn left as far as possible – minimum operating
pressure.
Transport by crane
Straps or cables (not wire cables) should be used when
transporting the unit using a crane.
0
1
DR
UC
K/
Pre
ssu
re
22
25
24
23
Placing into operation
1. Before connecting to the electricity supply ensure
that the supply voltage corresponds with the details
on the rating plate.
The connection should be made using a shockproof
socket earthed according to regulations.
2. Screw the special high-pressure hose (fig. 12, item
1) onto the high-pressure filter with open-ended
spanner.
Screw connection socket into the high-pressure
hose.
Screw the spray gun with the selected tip onto the
high-pressure hose.
When tightening and loosening the high-
pressure hose (fig. 12, item 1), hold screwed
socket of the high-pressure filter with open-
ended spanner.