EP3000
DRUCK/
Pressure
1
2
Explanatory diagram WAGNER EP 3000
Switch off unit and release the pressure in the unit
when working on the high-pressure filter.
Attention:
Never
unscrew the filter housing (fig. 2, item 1)
while still under pressure if the high pressure filter is
blocked.
Correct procedure:
1. Switch off unit.
2. Remove mains plug from the socket.
3. Release the safety unit on the spray gun and
open trigger.
4. Open release tap (2) – lever relocated.
5. Unscrew the filter housing.
6. Clean or replace filter insert.
26
EP3000
DRUCK/
Pressure
WA
GN
ER
G1
5
1
3
4
5
6
7
9
8
16
10
13
12
2
15
11
14
1
Spray gun G 15
2
Electric motor
3
Gear unit
4
Material feed pump
5
Intake hose with filter
6
Return hose
7
Trolley
8
Release valve
9
High-pressure filter
10 Switch box
11 Motor safety switch (400 V)
12 Motor safety switch (230 V)
13 Pressure regulator
14 Pressure gauge
15 Mains cable
16 Special high-pressure hose 15 m
GB