The following compand is used in the GSM-CTL-AC : 

#PWD

:  

 

Password 

#CAP

 

  Change 

password 

#WHL

:   

 

White List (add or remove numbers) 

#GOT

:   

 

Relay working output delay time 

#ALARM

:    

Alarm information setting 

#MODE:    

Relay mode 

#CSQ

 

  Check 

Signal 

Quality 

#SCA:   

 

Set service center address 

#STATUS

:   

Check status 

Once you issue a command with an SMS, you will receive a confirmation SMS with OK 

if everything is correct or Err if there is an Error. 

GSM-CTL-AC SMS COMMAND LIST: 

#PWD Password.  

This command must always come first 6 digits as a password. 
The standard default one, when the device comes from the factory, is 123456. 
We suggest that you change it, using the #CAP command. 
In all the following examples we will use 123456 as an example of password. 

 
#CAP Change Password
.  

Use this command to change the password with a new one that you will chose for your device 
( don't forget it or you will have to send the unit back to us to reset it, and this has a cost ) 
The #CAP command must be issued 2 times to be sure you don't digit a wrong one. 
OF course it must be preceded by the old password. 
For example, to change the password 123456 into the new password 333444 you need to send the 
following SMS: 

 
#PWD123456#CAP333444#CAP333444 

Acknowledge SMS: PWD SETUP OK   
If you wrote correctly, or an Error message if you made a mistake. 
If the old password is error,then conformation would be :

 Error Old Password

 

If you input two different new password,then reply would be :

 Error New Password,Please Check the 

input again

 

 

#WHL White List

This is the command that you will use most. it is used to add or remove numbers that are enabled 
to control the relay sets into the White List. You can add up to 200 numbers in the list. Every 
position must be indicated in the command and we advise you to keep a list written somewhere to 
know which numbers are in and in which position. 
• To add a number, the syntax of the command is the following: 

#PWD123456#WHL01=61143815 

Acknowledge 

would be : 

WHL01 SET TO 61143815 OK

 

Where 01 is the position in the list and 61143815 is the number enabled. 

Summary of Contents for GSM-CTL-AC

Page 1: ...WAFER GSM CTL AC REMOTE CONTROL UNIT http www waferstar com GSM CTL AC MANUAL SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...p to 6000W CONNECTOR DESCRIPTION ADVANTAGES OF WAFER GSM CTL AC 2 channels AC240V 30A 50Hz relay contact and AC240V 12A 50Hz relay contact No call charges to operate from phone calling DIP Switch to s...

Page 3: ...tor you want to use with the right direction according to the following pictures Note You must remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work In...

Page 4: ...lowing three slow flash to show the send out reply SMS Normally D6 is flashing quickly when power up and after about some minutes it will go to flash slowly about 2 seconds per time You can program th...

Page 5: ...back to us to reset it and this has a cost The CAP command must be issued 2 times to be sure you don t digit a wrong one OF course it must be preceded by the old password For example to change the pas...

Page 6: ...OT Relay working output delay time This command is useful in case you need to keep the Relay output working longer The standard time is 0 3 seconds 300 ms You can change it with the GOT command The sy...

Page 7: ...the relay sets in any condition Better if above 16 You should add an external antenna if this is not the case or eventually even change operator with another that serves your area better PWD123456 CS...

Page 8: ...your control number properly into the device memory GSM CTL AC reject the call after two dialing tone but the relay doesn t work Check the DIP switch if you setup the relay working mode at phone call...

Page 9: ...and other devices as are air conditioning and heating connected directly or through external relay modules Each relay output has NO NC and COM contacts Note Power supply for the load1 mustn t exceed 3...

Page 10: ...vices of WEIFU GSM Modules For further information and queries kindly contact Email coinco_cn yahoo com cn Web www waferstar com Tel 0086 21 51870528 Also accessible via our online MSN service frank_i...