background image

Europe

a

Dometic Austria GmbH

Neudorferstrasse 108
2353 Guntramsdorf

+43 2236 908070

+43 2236 90807060

Mail: [email protected]

h

Dometic Switzerland AG

Riedackerstrasse 7a
CH-8153 Rümlang (Zürich)

+41 44 8187171

+41 44 8187191

Mail: [email protected]

l

Dometic Denmark A/S

Nordensvej 15, Taulov
DK-7000 Fredericia

+45 75585966

+45 75586307

Mail: [email protected]

m

Dometic Spain S.L.

Avda. Sierra del Guadarrama, 16
E-28691 Villanueva de la Cañada
Madrid

+34 902 111 042

+34 900 100 245

Mail: [email protected]

p

Dometic S.N.C.

ZA du Pré de la Dame Jeanne
F-60128 Plailly

+33 3 44633500

+33 3 44633518

Mail: [email protected]

q

Dometic Finland OY

Mestarintie 4
FIN-01730 Vantaa

+358 20 7413220

+358 9 7593700

Mail: [email protected]

C

Dometic Italy S.p.A.

Via Virgilio, 3
I-47100 Forlì

+39 0543 754901

+39 0543 756631

Mail: [email protected]

L

Dometic Norway AS

Skolmar 24
N-3232 Sandefjord

+47 33428450

+47 33428459

Mail: [email protected]

N

Dometic Benelux B.V.

Ecustraat 3
NL-4879 NP Etten-Leur

+31 76 5029000

+31 76 5029090

Mail: [email protected]

U

Dometic Scandinavia AB

Gustaf Melins gata 7
S-42131 Västra Frölunda (Göteborg)

+46 31 7341100

+46 31 7341101

Mail: [email protected]

4

Dometic UK Ltd.

Dometic House · The Brewery
Blandford St. Mary
Dorset DT11 9LS

+44 844 626 0133

+44 844 626 0143

Mail: [email protected]

Ov Middle East

8

Dometic Australia

1 John Duncan Court
Varsity Lakes  QLD 4227

+61 7 55076000

+61 7 55076001

Mail: [email protected]

5

WAECO Impex Ltd.

Suites 2207-2211 · 22/F · Tower 1
The Gateway · 25 Canton Road,
Tsim Sha Tsui · Kowloon
Hong Kong

+852 24611386

+852 24665553

Mail: [email protected]

7

WAECO Impex Ltd.

Taipei Office
2 FL-3 · No. 56 Tunhua South Rd, Sec 2
Taipei 106, Taiwan

+886 2 27014090

+886 2 27060119

Mail: [email protected]

6

Dometic AB

Regional Office Middle East
P O Box 74775
Dubai, United Arab Emirates

+971 4 321 2160

+971 4 321 2170

Mail: [email protected]

0

Dometic Marine Division

2000 N. Andrews Ave. Extension
Pompano Beach, FL 33069 USA

+1 954 973 2477

+1 954 979 4414

Mail: [email protected]

k

Dometic WAECO International GmbH

Hollefeldstraße 63 · D-48282 Emsdetten

 +49 (0) 2572 879-195 · 

 +49 (0) 2572 879-322

Mail: [email protected] · Internet: www.dometic-waeco.de

www.dometic-waeco.com

3.0

3

.2

0.

016

1

8

0

7/

20

11

_MSP702_MSP2524.book  Seite 244  Donnerstag, 28. Juli 2011  9:45 21

Summary of Contents for SinePower MSP 702

Page 1: ...sanleitung EN 34 Sine wave inverter Instruction Manual FR 56 Onduleur sinuso dal Notice d emploi ES 82 Convertidor de ondas seno Instrucciones de uso IT 107 Inverter sinusoidale Istruzioni per l uso N...

Page 2: ...I Per ottenere maggiori informazioni sull ampia gamma di prodotti Dometic WAECO possibile ordinare una copia gratuita e non vincolante del nostro Catalogo all indirizzo Internet www dometic waeco com...

Page 3: ...SinePower 3 S ta tu s P o w e r L e ve l L o a d L e ve l In p u t O n O ff R e m o 1 3 4 5 6 7 2 1...

Page 4: ...SinePower 4 S ta tu s P o w e r L e ve l L o a d L e ve l In p u t O n O ff R e m o 5 1 2 3 4 2 NEG POS DIP FUSE REMOTE II REMOTE I INPUT 230V OUTPUT 9 8 5 7 6 1 2 3 4 3...

Page 5: ...SinePower 5 S ta tu s P o w e r L e ve l L o a d L e ve l In p u t O n O ff R e m o 1 2 4 NEG POS DIP FUSE REMOTE II REMOTE I INPUT 230V OUTPUT 2 1 5...

Page 6: ...SinePower 6 Inp ut Lo ad Po we r St atu s On Of f Re mo Le ve l Le ve l 2 1 6 S ta tu s P o w e r L e ve l L o a d L e ve l In p u t O n O ff R e m o 1 2 3 4 7...

Page 7: ...DIP FUSE REMOTE II REMOTE I INPUT 230V OUTPUT MSP 702 MSP 704 MSP 1012 MSP 1024 MSP 1512 MSP 1524 MSP 2012 MSP 2024 MSP 2512 MSP 2524 1 2 7 3 5 6 4 3 5 4 8 NEG POS DIP FUSE REMOTE II REMOTE I INPUT 23...

Page 8: ...SinePower 8 Input 230 V AC Output 230 V AC N MSP DC Input DC 230 V AC FI 2 RCD FI 1 RCD PE L1 N PE L1 N PE L N PE L1 6 5 4 1 3 7 2 0...

Page 9: ...SinePower 9 1 6 1 2 3 4 5 6 GND a 1 6 1 2 3 4 5 6 GND TR b 1 6 1 2 3 4 5 6 BAT BAT c 1 6 1 2 3 4 5 6 GND DC POWER d...

Page 10: ...ents 1 Notes on using the manual 35 2 Safety instructions 35 3 Scope of delivery 38 4 Accessories 38 5 Target group for this manual 38 6 Intended use 39 7 Technical description 39 8 Fastening the inve...

Page 11: ...mbol describes the result of an action fig 1 5 page 3 This refers to an element in an illustration In this case item 5 in figure 1 on page 3 Please observe the following safety instructions 2 Safety i...

Page 12: ...ended Do not operate the device in a damp or wet environment Do not operate the device near any flammable materials Do not operate the device in areas that are potentially explosive Maintenance and re...

Page 13: ...ble in the same duct Fasten the cables securely Lay the cables so that they cannot be tripped over or damaged 2 3 Operating the appliance safely Operate the device only if you are certain that the hou...

Page 14: ...e device No in fig 1 page 3 Description 1 Inverter 2 Holders MSP 702 MSP 704 MSP 1012 MSP 1024 MSP 1512 MSP 1524 4 holders MSP 2012 MSP 2024 MSP 2512 MSP 2524 6 holders 3 Connection cable with safety...

Page 15: ...to the chassis 7 Technical description The inverters can be operated wherever a 12 Vg connection SinePower MSP 702 MSP 1012 MSP 1512 MSP 2012 MSP 2512 a 24 Vg connection SinePower MSP 704 MSP 1024 MSP...

Page 16: ...he inverter switches off when the temper ature inside the device or the temperature on the cooling element exceeds a cut off value It restarts when the temperature returns to the restart value I NOTE...

Page 17: ...The Power Status LED displays the operational status 3 The Load Level LED displays the power being supplied 4 The Input Level LED displays the input voltage range 5 Drill holes for securing the exhaus...

Page 18: ...10 3 10 6 V 20 5 21 2 V Red 10 6 11 0 V 21 2 21 8 V Orange 11 0 12 1 V 21 8 24 1 V Green 12 1 14 2 V 24 1 28 6 V Orange flashing 14 2 15 0 V 28 6 30 0 V Red flashing 15 0 V 30 0 V Display Power MSP 7...

Page 19: ...the back side of the inverter must remain clear For ambient temperatures higher than 40 C such as in engine or heating compartments or direct sunlight the heat from the inverter under load can lead to...

Page 20: ...5 1 page 5 with the clip over the edge on the back side of the inverter fig 5 2 page 5 Screw the cable socket on with one screw in each of the four holes Fastening the inverter vertically Clip two hol...

Page 21: ...haust adapter in front of each fan and attach an exhaust hose 10 Connecting the inverter WARNING Danger of electrocution Incorrectly connecting the inverter can be fatal for the user The de vice can o...

Page 22: ...After running the cable secure it with cable ties to the clips on the cable socket Keep to the required cable cross section and fit a cable fuse as close to the battery as possible on the positive ca...

Page 23: ...the hood Loosen the safety bolt slightly fig 8 3 page 7 Push the cable lug fig 8 5 page 7 of the positive cable between the spring washer fig 8 4 page 7 and the positive terminal fig 8 6 page 7 Screw...

Page 24: ...into the socket distribution circuit see sample circuit diagram in fig 0 page 8 Sample circuit diagram legend WARNING Danger of electrocution If you wish to connect more than one appliance to the inve...

Page 25: ...nection cable to size according to the following circuit diagrams external switch voltage supply from the inverter fig a page 9 Control unit with relay or transistor circuit TR fig b page 9 external s...

Page 26: ...or the remote control the green Power Status LED fig 2 2 page 4 lights up Observe the following when using the device see also chapter Trou bleshooting on page 52 The inverter switches off if The batt...

Page 27: ...60 Hz The output voltage can be switched between 50 Hz and 60 Hz with the DIP switch S4 fig 3 1 page 4 WARNING Danger of electrocution Only adjust the S4 DIP switch when the respective frequency for t...

Page 28: ...flashing Input voltage too high The inverter is only intended for the voltage indi cated Slow flashing Input voltage too low The battery needs charging Check the cables and connections Occasional fla...

Page 29: ...cling centre or specialist dealer for details about how to do this in accord ance with the applicable disposal regulations 16 Technical data WAECO SinePower MSP 702 MSP 704 MSP 1012 MSP 1024 Item no M...

Page 30: ...ency up to 90 93 90 93 Ambient temperature for operation 0 C 40 C Ambient temperature for storage 30 C 70 C Dimensions W x D x H 225 x 465 x 117 mm 349 x 516 x 116 mm Weight 8 4 kg 15 5 kg WAECO SineP...

Page 31: ...Shutdown Restart MSP 702 MSP 1012 MSP 1512 MSP 2012 MSP 2512 15 3 V 14 3 V MSP 704 MSP 1024 MSP 1524 MSP 2024 MSP 2524 30 6 V 28 6 V Device Low voltage warning Low voltage Shutdown Restart MSP 702 MSP...

Page 32: ...Dometic Scandinavia AB Gustaf Melins gata 7 S 42131 V stra Fr lunda G teborg 46 31 7341100 46 31 7341101 Mail info waeco se 4 Dometic UK Ltd Dometic House The Brewery Blandford St Mary Dorset DT11 9LS...

Reviews: