EN
SinePower
Connecting the inverter to the exhaust system
45
9
Connecting the inverter to the exhaust
system
You can connect the inverter to an exhaust system. Thereby the warm ex-
haust is driven out of the internal chamber.
➤
Set the exhaust adapter (fig.
7
2, page 6) on the front side of the
inverter (fig.
7
1, page 6) over the fan, so that the screws fit into the
screw holes.
➤
Attach the exhaust adapter using the supplied screws.
➤
Connect the hose support (not included, fig.
7
3, page 6) to the exhaust
adapter.
➤
Attach the exhaust system hose (fig.
7
4, page 6) to the hose support.
I
NOTE
SinePower MSP 2012, MSP 2024, MSP 2512 and MSP 2524 are
equipped with two fans. With these devices, mount an exhaust
adapter in front of each fan and attach an exhaust hose.
10
Connecting the inverter
!
WARNING! Danger of electrocution!
Incorrectly connecting the inverter can be fatal for the user. The de-
vice can only be connected by a trained professional who is familiar
with the relevant VDE (German Engineering Society) regulations.
This chapter is solely intended for trained professionals who are familiar with
the relevant VDE (German Engineering Society) regulations!
10.1
Notes on connecting
!
WARNING! Danger of electrocution!
Never use the inverter on vehicles where the positive terminal
of the battery is connected to the chassis.
If you wish to connect more than one user to the inverter and in-
stall a socket distributor loop, you must arrange a circuit breaker
(residual current circuit breaker) and set a grounding bridge in
the inverter, see chapter “Connect multiple appliances” on
page 48.
_MSP702_MSP2524.book Seite 45 Donnerstag, 28. Juli 2011 9:45 21