HDC-150
Troubleshooting
43
11
Troubleshooting
Compressor does not run
Problem
Possible cause
Remedy
U
KL
= 0 V
There is an interruption in the
battery – electronics connection
Establish a connection
Main switch faulty (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replace the supply line
fuse
U
KL
U
ON
Battery voltage is too low
Charge the battery
Start attempt with
U
KL
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low
Replacing the battery
Cable cross section too small
Change the cable (see
table on page 35)
Start attempt with
U
KL
U
ON
Ambient temperature too high
–
Insufficient ventilation
Move the refrigerator to
another location
Condenser is dirty
Clean the condenser
Fan defective (if installed)
Replace the fan
Electric circuit between
the pins in the compres-
sor interrupted
Defective compressor
Replace the compressor
U
KL
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
_HDC150.book Seite 43 Donnerstag, 1. März 2012 11:59 11
Summary of Contents for CoolMatic HDC-150
Page 5: ...HDC 150 5 3 4 4 5 6 5 _HDC150 book Seite 5 Donnerstag 1 März 2012 11 59 11 ...
Page 6: ...HDC 150 6 7 9 8 6 10 11 7 _HDC150 book Seite 6 Donnerstag 1 März 2012 11 59 11 ...
Page 8: ...HDC 150 8 3 0 X 130 130 1 2 4 3 a _HDC150 book Seite 8 Donnerstag 1 März 2012 11 59 11 ...
Page 190: ..._HDC150 book Seite 190 Donnerstag 1 März 2012 11 59 11 ...
Page 191: ..._HDC150 book Seite 191 Donnerstag 1 März 2012 11 59 11 ...