EN
CoolFreeze
Technical data
41
I
NOTE
If the ambient temperature is above +32°C (+90 °F), the minimum
temperature cannot be attained.
Test/certificates:
The coolant circuit contains R-134a.
CF50
CF60
Connection voltage:
12/24 V
g
and 100–240 V
~
Rated current:
– 12 V
g
:
7.0 A
7.0 A
– 24 V
g
:
3.0 A
3.0 A
– 100–240 V
~
:
1.3 to 0.7 A
1.3 to 0.7 A
Cooling capacity:
+10 °C to –18 °C (+50 °F to 0 °F)
Category:
1
1
Energy efficiency class:
A+
A+
Energy consumption:
101 kWh/annum
102 kWh/annum
Usable capacity:
47 l
57 l
Climate class:
N, ST, T
N, ST, T
Ambient temperature:
+16°C –
+43 °C
+16°C –
+43 °C
Noise emission:
43 dB(A)
44 dB(A)
Dimensions (W x H x D) in mm:
630 x 480 x 360
630 x 582 x 360
Weight:
18 kg
21.6 kg
Summary of Contents for Coolfreeze CF-35
Page 4: ...CoolFreeze 4 100 240V AC FUSE 12 24V DC 1 2 3 4 1 2 1 5 ...
Page 5: ...CoolFreeze 5 6 CF50 CF60 A B 1 2 3 4 5 6 7 1 2 8 ...
Page 281: ......
Page 282: ......
Page 283: ......