wc_tx003097gb.fm
39
LTN 6L-V
Operation
4.16
Emergency Shutdown Procedure
General
procedures
If a breakdown or accident occurs while the machine is operating, follow the
procedure below:
1. Stop the engine.
2. Disconnect tools.
3. Lower the tower.
4. Allow the machine to cool before opening the cabinet.
5. Contact the rental yard or machine owner for further instructions.
Hydraulic
release valve
The hydraulic pump
(b)
is equipped with a pressure release valve
(c).
This valve
enables the tower to be lowered manually.
If electrical power is lost, or the tower switch is inoperable, pull out and hold the
knob on the pressure release valve. The hydraulic cylinder will retract and the
tower will lower. Push the knob to close the valve after the tower is fully lowered.
WARNING
Crushing / striking hazard.
f
Verify that no one is standing next to the machine while the tower is being low-
ered.