wc_tx003097gb.fm
38
Operation
LTN 6L-V
4.14
Automatic Shutdown
Description
This machine is equipped with a low oil, high temperature automatic shutdown
system. This system will automatically interrupt the fuel supply to the engine if the
oil pressure drops too low or the engine exceeds normal operating temperatures.
Resetting
after
automatic
shutdown
If an automatic shutdown occurs, the engine will stop. Return the key switch to the
off position to reset the system.
See
Troubleshooting
or contact Wacker Neuson Product Support if automatic
shutdown frequently occurs.
4.15
Stopping the Machine
NOTICE:
Do not stop the machine without turning off the lights. Damage to the
electrical generator will occur.
Procedure
Follow the procedure below to stop the machine.
1. Remove all connected loads from the machine.
2. Turn the circuit breakers
(a, b, c)
off.
3. Rotate the starting key
(q)
to the “OFF” position.
wc_gr009360
q
230VAC
b
c
a