Faults
T01052GB
30
8.
Faults
8.1
Disturbance on the machine console
Pressing the ”I” (d) button does not activate the machine – LED ring (b)
does not illuminate
The charge control lamp (f) does not extinguish while motor is running
The oil control lamp (c) does not extinguish while motor is running
Cause
Remedy
The vibratory plate’s on-board battery
is discharged.
Charge the battery and check the
functionality of the charge regulator if
necessary.
Button defective.
Replace the button with an original
replacement part.
Button has no electrical contact.
Check connection and repair.
LED ring has no electrical contact.
Check connection and repair.
Cause
Remedy
The on-board battery is not receiving a
charge.
Check the relevant connections or
ask Wacker service for assistance.
Regulator or alternator is defective.
Replace the regulator or ask Wacker
service for assistance.
Cause
Remedy
Engine oil level too low.
Fill up with engine oil.
Oil pressure switch defective.
Replace the oil pressure switch with
an original replacement part.
Oil pressure switch has no electrical
contact.
Check connection and repair.
c
d
b
f
e