Operation
T01044GB
20
6.2
Activating the machine
1.
Machine console
Press the ”I” button for at least one second – the yellow LED ring (b)
will illuminate.
2.
Sender
Move the rocker switch (h) forward to ”I” – the green LED (m) starts
blinking regularly.
3.
Point the sender at the receiver eye (a) on the machine – the yellow
LED ring (b) blinks.
LED ring (b) blinks slowly: All functions are activated.
LED ring (b) blinks rapidly: The operator is located in the machine’s
safety zone; all of the machine’s movements are deactivated.
Charge the transmitter’s rechargeable battery daily, at the latest
after the end of the working day, in the external battery charger.
The transmitter’s rechargeable battery can remain in the battery
charger for an unlimited period of time.
In accordance to the law the operators working place is at the rear end
of the machine.
An analogous inversion of the travel and steering direction can take
place if the operator is located in a position different to the designed
working position.
b
a
m