Maintenance
T01051GB
25
7.
Maintenance
7.1
Maintenance schedule
Check all external screw connections for tight fit appox. 8 hours alfter first operation.
Component
Maintenance work
Maintenance interval
Valve clearance
Check, set to 0,1 mm when engine is cold.
approx. 20 hours after
initial start-up
Drive engine
First oil change and filter.
25 hours after initial
start-up
Air filter
Check - clean or replace if necessary.
daily
Drive engine
Check oil level - top up if necessary.
Control panel
Check oil level - top up if necessar.
monthly
Protective
Check fastening screws of protecting frame for
frametight fit.
V-belt
Check V-belt, if. nec. replace.
Drive engine
Changing the oil and oil filter.
every 150 h
Exciter
Check oil level, top up if necessary.
Exciter
Oil change
every 250 h, or latest
every 6 months
Control panel
Exchange the suction filter.
every 250 h
Injection nozzle
Functioning check 175 bar, adjust if repair or
replace.
every 300 h
Drive engine
Retighten all accessible screw connections.
Battery
Check acid level - top up with distilled water if neces-
sary.
Valve clearance
Check, set to 0,1 mm when engine is cold.
Drive engine
Fuel - change filter.
every 500 h
Take engine to Wacker service station for
inspection.
every 2000 h