![Wacker Neuson CT 36-400E Operator'S Manual Download Page 30](http://html1.mh-extra.com/html/wacker-neuson/ct-36-400e/ct-36-400e_operators-manual_3136278030.webp)
Maintenance
CT 36-400E
30
3.7
Electrical Schematic
See Graphic: wc_gr001178, wc_gr001179
Ref.
Description
Ref.
Description
A
Motor
B
Control box
1.
Phase-sensing module
6.
Contacts from selector switch
2.
Transformer
7.
Selector switch
3.
Operator Present lever
8.
Motor overload switch
(located in motor)
4.
Contactor A
9.
Fuse
5.
Contactor B
9
I
0
L1
L2
L3
U1
V2
V1
W2
U2
W1
3L2-A
13 14
9 10
3L2-B
5 6
1 2
15 16
11 12
7 8
3 4
1L1-B
24
23
18
22
20
21
19
17
5L3-A
400V
24V
L3
14
11
L1
L2
L1 L2 L3
1L1 3L2
13 15
5L3
18
A1
2T1 4T2 6T3
A2
24
11
9
A
B
1L1 3L2 5L3
A1
2T1 4T2 6T3
A2
1
2
3
4
5
5L3-B
1L1-A
6
8
wc_gr001178