Maintenance
29
3.5
Storage
If trowel is being stored for more than 30 days:
Cover trowel and motor and store in a clean, dry area.
3.6
Troubleshooting
Problem / Symptom
Reason / Remedy
Trowel does not develop full
speed.
•
Power supply is not proper voltage.
•
Clean debris from moving parts and trowel blades.
Motor runs; poor trowel opera-
tion.
•
Check belt for wear or damage. Tighten belt if neces-
sary.
•
Clean debris from moving parts and trowel arms.
Motor does not run, or runs
erratically.
•
Check motor on/off switch position.
•
Phase rotation of motor may be mismatched with the
power supply. Turn on/off switch to opposite side.
•
Check fuse in control box. Replace if necessary.
Motor stops, won't restart.
•
Motor overload switch has tripped. Contact Wacker
Corporation or a certified electrician.
•
Check fuse in control box. Replace if necessary.