Troubleshooting
Troubleshooting rechargeable battery 12.2
53
[en] | 02/2022 | 5100060593 | APS | Operator’s Manual
12.2
Troubleshooting rechargeable battery
Pictogram
Status control light
Possible cause
Remedy
Control light rechargeable
battery error is lit.
Contact error of connection
strip.
Clean and if necessary dry the
contacts.
Activating the rechargeable
battery too quickly.
Deactivate the rechargeable bat-
tery and only activate it again
after 10 - 15 seconds.
Incorrect sequence when
activating the rechargeable
battery.
First activate the rechargeable
battery and then start the ma-
chine.
Hardware error or software
error.
Activate rechargeable battery
again and acknowledge error by
push button.
Have the rechargeable battery re-
paired.*
Overtemperature/undertem-
perature control light lights
up.
Temperature error (too high
or too low temperature).
Operate the rechargeable battery
only within the permissible tem-
perature range.
Allow the equipment to cool down
if necessary.
Activate rechargeable battery
again.
Diagnosis control light lights
up.
The rechargeable battery
was disabled due to a fault.
Have the rechargeable battery re-
paired.*
* Have this work carried out by a service partner.
12.3
Troubleshooting battery charger
WARNING
Danger to life due to unauthorized troubleshooting!
►
If faults occur on this machine which are not described in these oper-
ating instructions, contact the manufacturer.
►
Do not rectify faults on your own.
Fault
Possible cause
Remedy
The rechargeable battery is not
charged.
Connection plug not connected cor-
rectly.
Connect connection plug correctly.
Supply cable not connected to
power source.
Plug supply cable into power source.
The rechargeable battery is defect-
ive.
Contact service partner.
Battery charger is defective.
12
Summary of Contents for APS1030