Technical Manual
WDGA with EtherCAT
4 - EtherCAT
© Wachendorff Automation GmbH & Co. KG
32
Rev.1.09
Object Name
Idx
Description
Data size
(bit)
ro
rw
co
Map
Default
6410h
High-
resolution
area state
register
00h Number of status bits
of the work area
Unsigned8
co
Yes
01h
01h Status of the high-
resolution area
state register,
00h = in the work area,
03h above,
05h below the
work area
Unsigned8
ro
00h
6411h
High-
resolution
work area
low limit
00h Lower limit of the high-
resolution work area
Unsigned8
co
no
01h
01h Change of the high-
resolution work area
low limit
Signed64
rw
0000 0000
0000 0000h
6412h
High-
resolution
work area
high limit
00h Upper limit of the high-
resolution work area
Unsigned8
co
no
01h
01h Change of the high-
resolution work area
high limit
Signed64
rw
7FFF FFFF
FFFF FFFFh
6500h
Operating
status
00h Contains the values
from object 6000h
Unsigned1
6
ro
no
6501h
Single-turn
resolution
00h Display of the single-
turn resolution
Unsigned3
2
co
no
0001 0000h
6502h
Number of
distinguishab
le revolutions
00h Display of the multi-
turn resolution
Unsigned3
2
co
no
ST:
0000 0001h
MT:
FFFF FFFFh
6503h
Alarms
00h Alarm in the event of a
malfunction
Unsigned1
6
ro
Yes
6504h
Supported
alarms
00h Display of the alarms
implemented in the
encoder
Unsigned1
6
co
no
0001h
6505h
Warnings
00h Warning in the event of
a deviation in the
operating parameters
Unsigned1
6
ro
Yes
6506h
Supported
warnings
00h Display of the warnings
implemented in the
encoder
Unsigned1
6
co
no
7001h
6507h
Profile and
software
version
00h The first 4 digits =
software version, the
next 4 digits = profile
Unsigned3
2
co
no
0100 0400h
6508h
Operating
time
00h Not supported
Unsigned3
2
co
no
FFFF FFFFh
Table 4.26: Device-specific objects 6410h - 6508h