INSTALLATION INSTRUCTIONS

Adjustable Beam Wall Wash 

5222

STEP 3: DIMMING ADJUSTMENT
1.    Use a Philips head screwdriver to adjust the dimming dial.
2.    Rotate until the arrow on the dial is pointed at the desired wattage. 
        The wattage may be adjusted to the pre-existing tabs or any value        
        in between.
3.     The lower the wattage, the dimmer the fixture will be. 
4.    Please refer to the yellow tag that is included in the packaging to  
       determine the size of the required transformer.

STEP 4: BEAM ANGLE ADJUSTMENT:
1.    Note the three pre-determined beam angles on the beam angle  
       changing dial.
2.    Use the provided Hex Key to slightly loosen the set screw one or  
        two turns. Do not remove set screw from the fixture.
         

CAUTION:

 Do not remove set screw from the fixture.

         It should only be removed from the fixture for servicing.
         Consult factory for service instruction.
3.    Hold the fixture body and rotate the dial until the arrow is aligned  
       with the desired beam angle. This beam angle may be one of the  
       pre-determined markings or any number in between.
         

CAUTION:

 Keep the arrow marking on the fixture body between         

         the beam angle range.
4.    Tighten the set screw until it stops. Do not over tighten. 

Set Screw

Beam Changing Dial

Beam Angle Marking

Fixture Body

Rotation

NEMA

4X3

NEM

A

5X4

NE

MA

6X5

4x3

(60 H x 35 V)

5x4

(90 H x 60 V)

6x5

(120 H x 90 V)

STEP 5: VERTICAL FIXTURE HEAD ROTATION ADJUSTMENT
1.    Note the fixture head can be rotated 90 degrees to achieve vertical  
        wall wash applications.
2.    Hold fixture body with one hand and rotate the fixture head with  
        another hand to 90 degree.
3.    Loose thumb screw and swap the horizontal shroud with a              
        vertical shroud. 

NOTE:

 Vertical shroud is not provided (sold separately).

Rotation

NEMA

4X3

NEM

A

5X4

NE

MA

6X5

5x6

(90 H x 120 V)

3x4

(35 H x 60 V)

4x5

(60 H x 90 V)

*8

*15

*22

*24

Model: 5222

*Numbers not printed

*3