![WABCO iABS 2S/1M Standard Maintenance Manual Download Page 86](http://html1.mh-extra.com/html/wabco/iabs-2s-1m-standard/iabs-2s-1m-standard_maintenance-manual_3100609086.webp)
86
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
18
1680
3 GIO
Component
Multiple
ITP
Func-
tions
GIO_
Powerstage -
(PwrStage4)
Voltage
Above
Normal or
Shorted High
A short circuit to
supply voltage was
detected at GIO2
pin 4.
- Check whether water or
moisture has entered into the
connector / dummy cap and
check the seals for proper
fi
t.
- Check whether a function
has been parameterised on
this slot in addition; if this is the
case, then:
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors
- Test the cable for continuity
from end to end.
- Check whether the cable is
frayed.
18
1680
4 GIO
Component
Multiple
ITP
Func-
tions
GIO_
Powerstage -
(PwrStage4)
Under-
voltage/
Short Circuit
to Ground
A short circuit
to ground was
detected at GIO2
pin 4.
- Check whether water or
moisture has entered into the
connector/ dummy cap and
check the seals for proper
fi
t.
- Check whether a function
has been parameterised on
this slot in addition; if this is the
case, then:
- Check the cable between
modulator and the connected
component.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether the cable is
frayed.
Summary of Contents for iABS 2S/1M Standard
Page 148: ...148 Troubleshooting Fig 9 9 4017182a...
Page 149: ...149 Troubleshooting Fig 9 10 4017180a...
Page 150: ...150 Troubleshooting Fig 9 11 4017173a...
Page 156: ...156 Troubleshooting Fig 9 15 4017183a...
Page 174: ...174 Troubleshooting Fig 9 35 4017186a...
Page 187: ...187 Notes Notes...