68
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
9
9
3
Internal
Modulator
Valve
N/A
H1 Trailer
Modulator/
Solenoid
Valve Control
-
Overvoltage/
Short to
Supply
Voltage
ECU has detected
an over voltage/
short to supply
voltage condition
on the internal H1
modulator.
- Verify the ABS ECU power
connector is seated properly
and has no signs of moisture
or corrosion.
- Verify proper power, ground
at the main ABS ECU power
connector and load test the
power and ground circuit.
9
9
4
Internal
Modulator
Valve
N/A
H1 Trailer
Modulator/
Solenoid
Valve Control
- Under-
voltage/
Short Circuit
to Ground
ECU has detected
an undervoltage/
short to ground
condition on
the internal H1
modulator.
- Verify the ABS ECU power
connector is seated properly
and has no signs of moisture
or corrosion.
- Verify proper power, ground
at the main ABS ECU power
connector and load test the
power and ground circuit.
9
9
5
Internal
Modulator
Valve
N/A
H1 Trailer
Modulator/
Solenoid
Valve Control
-
Supply Cable
Interruption
ECU has detected
an open circuit on
the internal H1
modulator.
- Verify the ABS ECU power
connector is seated properly
and has no signs of moisture
or corrosion.
- Verify proper power, ground
at the main ABS ECU power
connector and load test the
power and ground circuit.
9
9
6
Internal
Modulator
Valve
N/A
H1 Trailer
Modulator/
Solenoid
Valve Control
-
Current
Too High
or Circuit
Grounded
ECU has detected
a high current\short
to ground condition
on the internal H1
modulator.
- Verify the ABS ECU power
connector is seated properly
and has no signs of moisture
or corrosion.
- Verify proper power, ground
at the main ABS ECU power
connector and load test the
power and ground circuit.
9
9
11
Internal
Modulator
Valve
N/A
H2 Trailer
Modulator/
Solenoid
Valve Control
-
FSC Actuator
Control
Timeout
Internal modulator
error.
- Switch off ignition for at
least 5s. If failure is no longer
present, there may be a
contact problem with the
supply voltage.
- Verify proper power, ground
at the main ABS ECU power
connector and load test the
power and ground circuit.
Summary of Contents for iABS 2S/1M Standard
Page 148: ...148 Troubleshooting Fig 9 9 4017182a...
Page 149: ...149 Troubleshooting Fig 9 10 4017180a...
Page 150: ...150 Troubleshooting Fig 9 11 4017173a...
Page 156: ...156 Troubleshooting Fig 9 15 4017183a...
Page 174: ...174 Troubleshooting Fig 9 35 4017186a...
Page 187: ...187 Notes Notes...