160
Troubleshooting
Condition
Experienced
Action to Take
Troubleshooting Detail
s
Trailer Bogie
Load is Not
Displayed
Ensure that Axle Load
Monitoring system is connected
correctly.
Refer to Figures 9.20 and 9.21 for correct installation.
Retrieve diagnostic information
via TOOLBOX PLUS™
Software.
Check for active faults with TOOLBOX PLUS™
Software and repair all faults found.
Ensure that Axle Load
Monitoring function is activated.
From the main screen of Trailer ABS diagnostics,
select the Modify pull-down. Select GIO con
fi
gurations
and active settings will be displayed. If it is not
activated then follow the procedures to activate the
function.
"Calibration
Unsuccess-
ful“ Message
Appears
While
Performing
Advanced
Calibration
Check the state of trailer.
(Unladen, Partially Laden,
Laden)
Select the appropriate state of trailer and enter the
exact trailer bogie load value that is displayed on weigh
station.