![WABCO iABS 2S/1M Standard Maintenance Manual Download Page 74](http://html1.mh-extra.com/html/wabco/iabs-2s-1m-standard/iabs-2s-1m-standard_maintenance-manual_3100609074.webp)
74
Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
14
251
12
Power
Supply
N/A
Power
Supply -
Under-
voltage
When
Driving
A deep
undervoltage has
occurred.
- Check the cable between
modulator and towing vehicle.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper fit.
- Check whether the cable is
frayed.
- If no other fault can be found,
replace the cable and/or
connectors.
15
253
2
Internal ECU
Error
N/A
Parameter
Setting -
External
Pin Not
Compatible
The parameter
setting is incorrect.
A GIO function is
parameterized to
an improper pin.
- Define the modulator
parameters again. If failure is
still present, contact WABCO
Customer Care Center at
855-228-3203 for assistance.
15
253
12
Internal ECU
Error
N/A
Parameter
Setting -
FSC-AC
Configur-
ation Failed
Internal checksum
error.
- Define the modulator
parameters again. If failure is
still present, contact WABCO
Customer Care Center at
855-228-3203 for assistance.
15
254
3
Internal ECU
Error
N/A
Trailer
Modulator -
(Uvent_g)
Voltage
Above
Normal or
Shorted High
Internal error.
- Switch ignition off for at least
5s. If the fault exists then,
contact WABCO Customer
Care Center at 855-228-3203
for assistance.
15
254
4
Internal ECU
Error
N/A
Trailer
Modulator -
(Uvent_g)
Under-
voltage/
Short Circuit
to Ground
Internal error.
- Switch ignition off for at least
5s. If the fault exists then,
contact WABCO Customer
Care Center at 855-228-3203
for assistance.
15
254
11
Internal ECU
Error
N/A
GIO Service
Indication
- Memory
Bit Service
Signal Set
Memory bit set for
service signal.
- Please perform defined
service activity.
15
254
12
Internal ECU
Error
N/A
Trailer
Modulator
- Err
Watchdog
Internal error.
- Switch ignition off for at least
5s. If the fault exists then,
contact WABCO Customer
Care Center at 855-228-3203
for assistance.
Summary of Contents for iABS 2S/1M Standard
Page 148: ...148 Troubleshooting Fig 9 9 4017182a...
Page 149: ...149 Troubleshooting Fig 9 10 4017180a...
Page 150: ...150 Troubleshooting Fig 9 11 4017173a...
Page 156: ...156 Troubleshooting Fig 9 15 4017183a...
Page 174: ...174 Troubleshooting Fig 9 35 4017186a...
Page 187: ...187 Notes Notes...