Diagnostics
Blink
Code
SPN
FMI
Suspect
Component
and Location
ITP
Function
Fault
Description
(FMI)
Cause
Repair Information
18
2752
3 Subsystem
Connection
ELEX
ELEX
Supply -
(CL30)
Overvoltage/
Short to
Supply
Voltage
A short circuit to
supply voltage
was detected
at subsystem
pin 1 (cl.30) for
the Electronic
Extension Module.
- Check the cable between
modulator and the ELEX.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed.
- Please open the fault
memory dialogue ELEX and
follow the error information
there. Contact WABCO
customer service for further
help.
- If no other fault can be
found, replace the connected
components.
18
2752
4 Subsystem
Connection
ELEX
ELEX
Supply -
(CL30)
Under-
voltage/
Short Circuit
to Ground
A short circuit
to ground was
detected at
subsystem pin
1 (cl.30) for
the Electronic
Extension Module.
- Check the cable between
modulator and the ELEX.
- Check for tight seat of the
connectors.
- Test the cable for continuity
from end to end.
- Check whether water or
moisture has entered into one
of the connectors and check
the seals for proper
fi
t.
- Check whether the cable is
frayed.
- Please open the fault
memory dialogue ELEX and
follow the error information
there. Contact WABCO
customer service for further
help.
- If no other fault can be
found, replace the connected
components.
Summary of Contents for iABS 2S/1M Standard
Page 148: ...148 Troubleshooting Fig 9 9 4017182a...
Page 149: ...149 Troubleshooting Fig 9 10 4017180a...
Page 150: ...150 Troubleshooting Fig 9 11 4017173a...
Page 156: ...156 Troubleshooting Fig 9 15 4017183a...
Page 174: ...174 Troubleshooting Fig 9 35 4017186a...
Page 187: ...187 Notes Notes...