PROBLEMS
ANOMALIES
POSSIBLE REASON
SOLUTIONS
The machine is not
working
Turned off
Turn on the machine through
general switch.(look. Pag. 16)
The spy of the general
switch is off.
Modelli: SV – 300; SV – 400
With out feeding
Verify the feeding plug.
The spy of the three-phase
switch is off.
Modelli: SV – 550; SV – 600;
SV- 600/500; SV – UNICA;
SV – 900/500
In the machines three phases the spy
of feeding is fed by one of the three
phases. If the spy doesn't ignite you
need to verify probably if you misses
the phase where the spy is laced.
Speak with the customer care.
Insufficient vacuum
in the chamber
Short time of vacuum
Increase the vacuum time with
the knob [
V
] look control panel
(pag. 16)
Wear gasket chamber
Replacment of the gasket
procedure (pag. 19)
The machine don’t
makes the cycle
The hand pressure trained on the lid
is insufficient.
Makes a good pressure with
both hands on the lid.
Active gas function
Deactivate the Gas function look
control panel (pag.16)
The chamber didn’t
close
Wear gasket chamber
Replacment of the gasket
procedure (pag. 19)
Verify that the support ( in
alluminium) are not weared , out
seating
or had let the fixing support.
Replace the fixing support.
Verify the electric valve on the back
of the tank.
Speak with the customer care
On the three-phase machine
Modelli: SV – 550; SV – 600;
SV- 600/500; SV – UNICA;
SV – 900/500
Verify the sense rotation of the
vacuum pump.
Speak with the customer care
Procedure ( pag. 15 )
Insufficient Vacuum
in the bag.
Bag in not a properly position
Put the bag in the middle of the
sealing bar with a protuberance
of 15 – 20 mm
Perforated Bag
Replace the bag
Sealing
The sealing is with burning
Time of sealing to high.
Reduce the sealing time, look
control panel ( pag. 16)
Irregular sealing with
vacuum loosing.
Time of sealing to low.
Increase the time of sealing,
look the control panel ( pag. 16)