6
Operation
To save any of the settings please follow the instructions below;
To edit the input settings please follow the instructions below;
To edit the output settings please follow the instructions below;
2. To save the settings, press the
“SAVE”
button to enter the preset save option.
You can save the setting into
“U-00”
-
“U-30”
.
Note that
“F00”
can not be saved into.
1. The tolerant preferred is
“GAIN”
, this ranges from -60dB - +12dB.
2. Now press the
“PEQ”
button to edit the parameter settings:
The Current filter location (DP24/36 is 1-8, DP48 is 1-6).
The scale of
“F”
is 20Hz - 20kHz,
“Q”
is 0.4 - 128 and
“G”
is -12dB - +12dB.
The style of the filter is PEAK: LOW/HIGH - SHELF, bypass On/Off.
3. Press the
“GATE”
button to edit the noise gate settings:
“THRESHOLD”
settings are from -90dB - -0dB
“ATT”
start up times range from 1mS - 200mS.
“RE”
times range from 1mS - 999mS.
4. Press the
“DELAY”
button to edit the delay settings: 0 - 682mS, 0 -234m, 0 - 769ft.
5. Press the
“X-OVER”
button to edit the high/low parameter settings:
“HP”
ranges from 20Hz - 20kHz.,
“LP”
ranges from 20Hz - 20kHz
There are three slanting rates for the high/low pass filter:
“BUTTERWORTH”
,
“BESSEL”
and
“LINKWITZ”
, the slanting rate is DP24/36 is -6dB - -48dB, DP48 is -6dB - -24dB.
6. Press the
“PHASE”
button to edit the phase settings:
The phase settings range from 0˚ - 180˚.
1. The tolerant preferred is
“GAIN”
, this ranges from -60dB - +12dB.
2. Now press the
“PEQ”
button to edit the parameter settings:
The Current filter location (DP24/36 is 1-8, DP48 is 1-6).
The scale of
“F”
is 20Hz - 20kHz,
“Q”
is 0.4 - 128 and “G” is -12dB - +12dB.
The style of the filter is PEAK: LOW/HIGH - SHELF, bypass On/Off.
3. Press the
“DELAY”
button to edit the delay settings: 0 - 682mS, 0 -234m, 0 - 769ft.
4. Press the
“X-OVER”
button to edit the high/low parameter settings:
“HP”
ranges from 20Hz - 20kHz.,
“LP”
ranges from 20Hz - 20kHz.
There are three slanting rates for the high/low pass filter:
“BUTTERWORTH”
,
“BESSEL”
and
“LINKWITZ”
, the slanting rate is 2 x 4/3 x 6 is -6dB - -48dB, 4 x 8 is -6dB - -24dB.
5. Press the
“PHASE”
button to edit the phase settings:
The phase settings range from 0˚ - 180˚.
6. Press the
“MATRIX”
button to edit the matrix settings:
All of the output channels can be selected from single or multiple input signals.
7. Press the
“COMP”
button to edit the compressor settings. The settings are as follows:
“THRESHOLD”
is -60dB - -0dB.
“A”
is1mS - 200mS,
“R”
is 1mS - 999mS.
The compress rate is 1:1, 1:1.3, 1:1.5 - LIMIT.