![Vyyo Inc. V290iA User Manual Download Page 58](http://html.mh-extra.com/html/vyyo-inc/v290ia/v290ia_user-manual_1058095058.webp)
F Ethernet Cable Specifications
50
V290iA User Guide
Ethernet Version 2 and IEEE 802.3 Physical
Characteristics
The table below lists the Ethernet Version 2 and IEEE 802.3 physical characteristics of
the Ethernet cable.
IEEE 802.3
Ethernet
10Base5
10Base2
10BaseT
Data rate (Mbps)
10
10
10
10
Signaling method Baseband
Baseband
Baseband
Baseband
Maximum
segment length
(in meters)
500 500
185 100 (Unshielded
twisted pair
−
UTP)
Media
50
−
ohm coax
(thick)
50
−
ohm coax
(thick)
50
−
ohm coax
(thin)
UTP
Topology Bus
Bus
Bus
Star
Ethernet Coaxial
−
type Connection Limits for
10
−
Mbps Transmission
The following table lists the Ethernet coaxial
−
type connection limits for 10
−
Mbps
transmission.
Parameter
10Base5
10Base2
Cable diameter
1 cm (0.4 in)
0.6 cm (0.25in)
Maximum segment
length
500 m (1640ft.)
152 m (500ft.)
Maximum network
length (with four
repeaters)
2500 m (8200ft.)
762 m (2500ft.)
Maximum
connections (taps
per segment)
100 30
Minimum
connection (tap)
spacing
2.5 m (8.2 ft.)