23
be a differential switch, with the rated breaking differential current of 30 mA, or a residual current
circuit-breaker with the specified rated breaking differential current shall be installed in a line after
the automatic circuit breaker. Any other consumers must not be connected to the automatic circuit
breaker.
2.1.1.15 The EH must not be operated without certified CU.
2.1.1.16 The EH shall be [properly grounded.
2.1.1.17 Before Electric heater switching on, make sure that foreign items are not available on the EH
and inside it.
2.1.1.18 The EH shall be operated only vertically.
2.1.2 Electric heater connection to the electrical mains and water supply system. Preparation
to operation.
2.1.2.1 Open the package, check the delivery set, remove protective and packing materials.
2.1.2.2 Install the EH in the bath or sauna room.
2.1.2.3 Install the CP at the height of 1.5 m outside the sweating room, in a dry location, easily
accessible for visual inspection and maintenance.
2.1.2.4 Install the temperature sensor in the bath or sauna room, in a procedural area, approximately
at a level of head of a person, who sits on the upper birth. The sensor must not be installed in close
proximity to the EH and entrance door of the sweating room or above them. Cover the temperature
sensor with a decorative wooden cover.