- 6 -
1-6. AC Source Requirement
OXXO
TM
Series
“K” Model power supply is designed to operate from a nominal AC 220V/47~63Hz single
phase. If the unit is used in other countries with different voltage and frequency rating than the
specifications on the rear panel of the unit, then the built-in input source circuitry must be modified. In
this case, contact VuPOWER(
) for support
○
Changing AC Source Requirement
1. Remove the cover, then locate the
“AC Source Alteration Circuit Board” (see diagram below), and
remove it from the slot.
2. Find the correct AC source and insert it back into the slot in the direction of the arrow indicated in
front of selected AC source rating
Example of chainging AC Source Alteration Circuit Board
[ AC Source Alteration Circuit Board ]
○
Replacing the Fuse
Unplug the power cord then remove the fuse holder located above the AC cord socket. Replace with
fuse with capacity of ~250V 6.3A
Replacing the Fuse
.
[ Replacing the Fuse ]
Warning
Make sure to unplug the power cord prior to changing the AC Source Alteration
Circuit Board or the fuse.
1. Product Information.