- 26 -
3-13. Calibration Recover
This feature restores the calibration status to factory calibration.
[ IMPORTANT ]
This feature CAN NOT replace user
’s modification
○
Voltage Recover
No.
Key Operation
Display Panel
Description
1
P1 or P2
SET-Limit
SET-Cal_V Recover
Select desired output port.
Press
“SETUP” button.
Use the arrows or the jog shuttle to
select.
“SET-Cal_V Recover”
2
SET-Cal_V Recover
Password ****
※
Factory default
- 1 2 3 4
Press
“SETUP” button.
Please enter 4 digit Password.
Use the arrows to move cursor.
Use the jog shuttle to select the
number for the password.
3
Cal-V recovered
P1 00.000V 0.000A
Press
“SETUP” button.
After 2 seconds, you will see Cal-V
recovered sign with formatting of
Voltage adjustment. You will exit
from Setup mode.
○
Current Recover
It is similar to voltage recover procedure.
Follow Voltage recover step 1 up until you reach Setup Menu, and choose
“SET-Cal_C
Recover
” Menu.