- 21 -
3
SET-Pattern
Repeat
– 001
SET-Pattern
Repeat
– 001
Press
“STORE” button to save number
of output
“Steps” then set the number of
repeats.
Use the arrows to change the location of
the cursor and use the jog shuttle to set
the value.
4
SET-Pattern
01 00.000V 00000S
SET-Pattern
01 00.000V 00000S
Press
“STORE” button again to save
number of repeats, then, set the voltage
and duration of
“Step 1”. Durating is
set in increments of seconds.
Use arrows and
“V/I” button to change
cursor location, and use the jog shuttle
to set voltage and duration of each
“Step”.
Press
“STORE” button to save and
repeat this process for all
“Steps” to be
programmed.
5
** OUTPUT OFF **
P1 00.000V 0.000A
When all
“Steps” are programmed press
“STORE” button to save and exit from
Setup.
Press
“OUTPUT ON/OFF” button again
to continue use.
○
Pattern output Operation
No.
Key Operation
Display Panel
Description
1
P1 or P2
Recall 01
06.000V 1.000A
Select the output port to use.
Press
“RECALL” button.
User can now select the
“Pattern Output”
to use.
2
Recall Pattern output
P1 06.000V 1.000A
Step : 01
Use the jog shuttle to select any saved
“Pattern Output”.
Once selection has been made, press
“RECALL” to execute.
Use
button to shut down output during operation.
When the
“Pattern Output” completes its cycle the display panel will indicate “OUTPUT OFF”.
3. Features