VOM with A.C. current tester (Any quality VOM
with a sensitivity of at least 20,000 ohms per volt
can be used)
•
Gear Puller to remove blower
•
Temperature tester (thermocouple type)
Special
•
Manometer
•
Clamp on amp meter
•
Spring force gauge, pull type with a minimum 30
pound full scale range (purchase locally)
•
RTV sealant, 736 DOW silicone high temp (P/N
542133) or equivalent
SPECIFICATIONS
AMPERAGE - 3 PHASE/ 60HZ
MODEL
TOTAL
POWER
(KW)
RECOMMENDED CIRCUIT
208V
240V
480V
208V
240V
480V
VC4ES
VC4ED
VC4EC
VC6ES
VC6ED
VC6EC
12.5
35
33
15
45
40
20
NOTES:
1
Amperage values in the table are nominal. Tolerance is +5/-10%.
2
Complied in accordance with National Electric Code, ANSI/NFPA 70, latest edition
AMPERAGE - 1 PHASE/ 60HZ
MODEL
TOTAL
POWER
(KW)
RECOMMENDED CIRCUIT
VC4ES
VC4ED
VC4EC
VC6ES
VC6ED
VC6EC
12.5
60
52
26
80
70
35
NOTES:
1
Amperage values in the table are nominal. Tolerance is +5/-10%.
2
Complied in accordance with National Electric Code, ANSI/NFPA 70, latest edition.
VC4E & VC6E Series Full Size Electric Convection Ovens - GENERAL
F25105 Rev. B (0217)