COOLING FAN
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE:
If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2.
removing wire nuts.
3.
Remove the screws securing the air deflector to
the fan then loosen the tab screw holding the fan
to the component panel. Rotate the tab so that
the fan will clear and remove the fan.
Fig. 35
4.
Reverse the procedure to install the replacement
fan and check for proper operation.
NOTE:
The fan must be installed so air is pulled from
outside the rear of the oven and blown into the control
area. The arrow on the fan body indicates "air flow"
direction and should be pointing toward the controls.
NOTE:
Ensure fan is seated "squarely" against the
air tube and the oven bottom.
NOTE:
The air deflector should be angled upwards
at approximately 30 degrees to properly direct the air
flow.
VC4E & VC6E Series Full Size Electric Convection Ovens - REMOVAL AND REPLACEMENT OF PARTS
Page 19 of 64
F25105 Rev. B (0217)