Fig. 9
TEMPERATURE PROBE (SOLID
STATE CONTROL)
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
1.
Remove the right side panel as outlined under
COVERS AND PANELS.
NOTE:
If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVER AND PANELS.
2.
Disconnect the probe leads from the solid state
temperature control.
3.
Remove the racks and right rack support.
4.
Remove the probe guard or mounting clips.
Fig. 10
Fig. 11
5.
Remove probe by pushing it through the oven
wall and into the control panel area.
NOTE:
The hole in the oven cavity wall does not line
up straight with the oven cavity outer shell, therefore
the probe must be removed at an angle.
6.
Reverse the procedure to install the replacement
probe.
7.
Adjust the temperature control as outlined under
SOLID STATE TEMPERATURE CONTROL
CALIBRATION in SERVICE PROCEDURES
AND ADJUSTMENTS.
HEATING ELEMENTS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
There may be multiple circuits. Be sure
all circuits are disconnected.
NOTE:
Starting with production in October, 2001, the
top cavity panel will have 3/4" square holes for easier
element removal. Ovens manufactured prior to this
date have 1/2" round holes that sometimes make it
difficult to remove elements thru the cavity. A serial
number cut off will
not
be available. Follow the
procedures for element removal as outlined below.
Front Access
1.
Remove the oven racks and rack supports.
2.
Remove the "top" door seal from the oven.
VC4E & VC6E Series Full Size Electric Convection Ovens - REMOVAL AND REPLACEMENT OF PARTS
F25105 Rev. B (0217)
Page 10 of 64