Electrical
• 120VAC supply. A 24VAC transformer provides
power for the fryer controls, basket lift controls (if
installed) and the filtering controls on
Kleenscreen™ battery fryers.
• Kleenscreen filter models require a separate
120VAC connection for the filter pump motor (5
amp draw).
Gas Pressures
Manifold (per fryer section):
• Natural - 4" W.C.
• Propane - 10" W.C.
Building supply pressure (Min):
• Natural - 5" W.C. (7" W.C. battery units)
• Propane - 11" W.C. (12" W.C. battery units)
NOTE:
Propane or Natural gases -14" W .C. (Max).
TOOLS
Standard
• Standard set of hand tools.
• VOM with AC current tester.
NOTE:
Any quality VOM with a sensitivity of 20,000
ohms per volt can be used.
• Temperature tester (thermocouple type).
• U-Tube Manometer.
Special
• Field service grounding kit P/N TL- 84919.
• Loctite 242 P/N 520228 or equivalent.
• Burndy pin extraction tool RX2025 GE1; Newark
Electronics Catalog Number 16F6666. Used for
removing pin terminals on Burndy connectors.
Input BTU Rating
GR SERIES
NO. OF
BTU/HR/SECTION
TUBES
GRD25
2
60,000
GRD35, GRC35
3
90,000
GRD45, GRC45
4
120,000
GRD65, GRC65
5
150,000
GRD85, GRC85
5
150,000
GR SERIES GAS FRYERS - GENERAL
Summary of Contents for GRC35
Page 29: ... 29 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION COMPONENT LOCATION ...
Page 30: ... 30 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX ...
Page 37: ... 37 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 39: ... 39 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 41: ... 41 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station ...
Page 48: ... 48 F 25114 Rev A 07 03 NOTES GR SERIES GAS FRYERS ...