– 24 –
F-25114 Rev.A (07-03)
GR SERIES GAS FRYERS - SERVICE PROCEDURES AND ADJUSTMENTS
SOLID STATE CONTROL
Operation
Refer to the Installation & Operations manual for specific
operating instructions.
Error messages
For information on solid state control error messages,
refer to “SOLID STATE CONTROL” under
“TROUBLESHOOTING”.
Programming
The solid state control’s “programming” mode is used to
set the controls operational parameters.
NOTE:
If a product key is active (timing), programming
mode can not be entered.
1. Press “V” key to enter programming mode. If the
PARAMETER LOCK feature is disabled, PROGRAM
MODE entry is immediate. If the PARAMETER LOCK
feature is enabled “LoC” will be displayed.
Use the following key sequence (password) to enter
PROGRAM MODE: LEFT BASKET/UP; LEFT
BASKET/UP; RIGHT BASKET/DOWN; RIGHT
BASKET/DOWN.
NOTE: If the proper key sequence is not entered within
6 seconds the controller exits PROGRAM MODE.
2. Beeper chirp’s on each successful keypress; If a key
is not pressed within 2 minutes, the control will
automatically exit programming.
3. To scroll through each of the PROGRAM ITEMS,
press “V” and release.
4. To exit PROGRAM MODE, at any time, press “V” and
hold for 1 second.
“gAS” or “ELEC”
Summary of Contents for GRC35
Page 29: ... 29 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION COMPONENT LOCATION ...
Page 30: ... 30 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX ...
Page 37: ... 37 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 39: ... 39 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 41: ... 41 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station ...
Page 48: ... 48 F 25114 Rev A 07 03 NOTES GR SERIES GAS FRYERS ...