– 45 –
F-25114 Rev.A (07-03)
GR SERIES GAS FRYERS - TROUBLESHOOTING
SOLID STATE OR COMPUTER CONTROL HARNESS PIN-OUTS
INTERFACE CONTROL BOARD PIN-OUTS
FRYMATE (DUMP STATION) WITH OPTIONAL HEATER
SYMPTOM
POSSIBLE CAUSES
No heat.
1.
Unplugged.
2.
Power switch off or inoperative.
3.
Main circuit breaker off or open.
4.
Malfunctioning heat assembly.
PIN NO.
INPUTS
PIN NO.
OUTPUTS
3
P1
24VDC Left Basket Lift
P6
Heat Demand Triac (24VAC)
2
P2
24VDC Right Basket Lift
P7
System Ground
P3
24VDC Heat Demand Control
P8
24VAC Left Basket Lift
3
P4
Control Common (-)
P9
24VAC Right Basket Lift
3
P5
Heat Demand Triac (24VAC)
—
—
P10
Relay Contacts (24VAC)
1
—
—
NOTES:
1. Relays connected internally. 2. To “TH” Terminal on gas valve (main). 3. To basket lift relay coils.
PIN NO.
INPUTS
PIN NO.
OUTPUTS
3
E1-1
24VAC Hot
E1-8
24VDC (+) Heat Demand
E1-2
24VAC Neutral
1
E1-9
Not used at this time
2
E1-3
Probe High (red)
E1-10
24VDC (+) Left Basket Lift
E1-4
Probe Low (white)
E1-11
24VDC (+) Right Basket Lift
E1-5
Drain Valve Interlock (24VAC) N.O.
E1-12
No connection
E1-6
Ignition Status (24VAC)
—
—
E1-7
Relay DC (-) Common
—
—
NOTES:
1. Connected to ground internally. 2. Available for external buzzer output (24VDC). 3. Outputs to
Interface Control Board.
Summary of Contents for GRC35
Page 29: ... 29 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION COMPONENT LOCATION ...
Page 30: ... 30 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX ...
Page 37: ... 37 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 39: ... 39 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 41: ... 41 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station ...
Page 48: ... 48 F 25114 Rev A 07 03 NOTES GR SERIES GAS FRYERS ...