– 33 –
F-25114 Rev.A (07-03)
GR SERIES GAS FRYERS - ELECTRICAL OPERATION
F. When the oil filtering process is completed, close
the manual drain valve to the fryer and allow the
fry tank to refill.
NOTE:
Drain valve interlock contacts close and
the position of the drain valve is indicated to the
cooking control.
G. When all filtered oil is returned to the fryer, retract
the filter valve handle.
1) Power is removed from pump motor.
H. Turn filter power switch off.
NOTE:
If using solid shortening, when all filtered
oil is returned to the fry tank and filter power
switch is off, open the filter drawer approximately
one inch. Allow the remaining shortening in the
line to drain into the filter tank to prevent possible
clogging after the shortening cools and solidifies.
Close the filter drawer when complete.
5. Computer Control:
A. The number of cooking cycle’s reach the filter
count setting.
B. The right side display indicates “FILTER” and will
flash when the fryer is idle.
NOTE:
A manual filter cycle can also be done at
any time by following the procedure outlined under
“SOLID STATE CONTROL” in steps 4B thru 4H.
Display will show “DRAINING” “TURN OFF”. If
desired, the filter timer can still be initiated.
C. Open the drain valve to the fryer section in need of
filtering and drain the frying oil/shortening into filter
tank.
NOTE:
If using solid shortening, allow hot
shortening to stand in filter tank for approximately
6 minutes prior to filtering.
NOTE:
Drain valve interlock contacts open and
the position of the drain valve is indicated to the
cooking control.
NOTE:
Steps 5D thru 5G should be performed in
immediate succession to start the filtering process
and the filter timer.
D. Turn filter power switch on.
1) Switch pilot light comes on.
E. Extend Filter valve handle of the same fryer
section.
1) Filter valve switch N.O. contacts close.
a. Power supplied to pump motor.
F. Pump motor circulates oil through filter until power
is removed.
G. Press either “TIME” key to start filter timer
countdown.
1) “FILTER” and the remaining filter time are
displayed.
H. Filter time expires:
1) “FILTER” “DONE” is displayed and the
electronic alarm will sound for approximately 5
seconds. Display then changes to “CLOSE”
“DRAIN”.
I. Close the drain valve:
1) “TURN OFF” is displayed.
NOTE:
Closing the drain valve before filter time
expires will stop the filter timer but will not reset the
filter counts. The “FILTER” prompt can only be reset
by completing a filtering cycle or disabling the
function in programming mode. Cycling the power will
not reset this prompt.
NOTE:
Drain valve interlock contacts close and the
position of the drain valve is indicated to the cooking
control.
J. When all filtered oil is returned to the fryer, retract
the filter valve handle.
1) Power is removed from pump motor.
K. Turn filter power switch off.
NOTE:
If using solid shortening, when all filtered oil is
returned to the fry tank and filter power switch is off,
open the filter drawer approximately one inch. Allow
the remaining shortening in the line to drain into the
filter tank to prevent possible clogging after the
shortening cools and solidifies. Close the filter drawer
when complete.
L. Turn the power switch off.
Summary of Contents for GRC35
Page 29: ... 29 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION COMPONENT LOCATION ...
Page 30: ... 30 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION POWER SUPPLY BOX ...
Page 37: ... 37 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 39: ... 39 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION ...
Page 41: ... 41 F 25114 Rev A 07 03 GR SERIES GAS FRYERS ELECTRICAL OPERATION Frymate Dump Station ...
Page 48: ... 48 F 25114 Rev A 07 03 NOTES GR SERIES GAS FRYERS ...