VTS2000 Series frequency inverter
- 37 -
F0.16
Carrier
frequency
setting
For occasions requiring silent operation, the carrier
frequency can be appropriately increased to meet the
requirements, but it will increase the heat generation
of the inverter.
When the inverter leaves the factory, the
manufacturer has set a reasonable carrier frequency.
Under normal circumstances, the user does not need
to modify this parameter.
2.0
~
16.0KHz
0.4
~
3.0KW
4.0KHz
4.0
~
7.5KW
3.0KHz
Model
setting
×
F0.17
V/F frequency
When P0.13=2 (multi-point V/F curve), users can
0.1
~
12.5Hz
×