VTS2000 Series frequency inverter
- 33 -
command
channel
selection
1
:
Terminal command channel
2 Communication command channel
F0.03
Frequency
setting
selection
0
:
Panel potentiometer
1
:
Digital setting 1, panel ▲, ▼ key adjustment
2
:
Digital setting 2, terminal UP / DOWN
adjustment
3
:
AVI analog setting (0
~
10V)
4
:
Combination setting
5
:
ACI setting (0
~
20mA)
6
:
Communication setting
7
:
Pulse setting
Note: When combination setting chosen, the
combination setting is selected in F1.15.
0
~
7
0
○
F0.04
Maximum
output
frequency
The maximum output frequency is the highest
frequency that the inverter is allowed to output, and
it is the benchmark for acceleration and deceleration
MAX
{
50.0,
【
F0.05
】}~
999.9Hz
50.0Hz
×