11 - SPOTLIGHT BULB REPLACEMENT
in universal blocks
Turn off power supply of filtration unit. Turn spotlight clockwise untill spotlight’s holders will not get in the slots on
the front part of filtration unit. Take out the spotlight from water carefully extending a reserve of cable. Take a
spotlight’s cup and unscrew counterclockwise decorative nut of spotlight. Remove a glass and take out a bulb.
Replace by new bulb. Then assemble the spotlight in the return sequence. Densely tighten a decorative nut of
spotlight. Insert a spotlight back on its place by holders into the slots and turn clockwise again so, that it will be fixed
on the front part of filtration unit.
ATTENTION!
It is forbidden to switch on spotlight if it is not completely submerged into water. Spotlight
works only with the safety transformer 150 VA.
12 - EQUIPMENT WINTERIZING
ATTENTION!
To make correct winterizing of your filtration equipment, apply for the help to your
territorial representative.
CAUTION!
All electric connections should be carried out by a qualified specialist-electrician with
observance of enclosed instructions.
If your filtration unit is used in the region with risk of low temperatures, we recommend you to make
complete conservation of your filtration unit (if the water will become frozen, some parts of filtration
equipment can be damaged).
For this purpose you should switch off the differential switch in the electrical control panel for the whole
conservation period. Turn off the pipeline of automatic water filling device and ensure water emptiness in
it. Empty the swimming pool up to the level of 1m from the upper edge of the pool. In the technical
compartment in the multiconductor connection box disconnect the electric motor wires. Unscrew pump’s
fixing nuts and take the pump out from the technical compartment. Ensure that after you have drained
your pump you store it in a dry place. It is necessary to turn the turbine manually 2-3 times during
winter.
With the help of industrial vacuum cleaner or compressor make the pipelines and the filtration equipment
free of water. If your filtration unit is equipped with heat exchanger, it is necessary with the help of
industrial vacuum cleaner or compressor to free heat exchanger and pipeline to it from water.
At the end of works close the cover of filtration compartment. Don’t forget to cover the technical