VSV VUB15 Installation Manual And User'S Manual Download Page 19

19

HYDRAULIC CONNECTION SCHEME OF HEAT EXCHANGER  

in universal blocks VU

В

15, VU

В

25 and VUB20/50  

Connect heat exchanger with gas boiler according enclosed scheme.

 

Choose the circulation pump of necessary capacity according enclosed table. 

Table of circulation pumps for heat exchanger 

Capacity of the circulating 

pump 

Power of the circulating 

pump

 

0,72 m

3

/h

15 kW

1,44 m

3

/h

29 kW

2,16 m

3

/h

44 kW

2,88 m

3

/h

59 kW

circulation pump
of heating

valves

circulation pump
of heat exchanger

thermal protection switch

  pipe      26/34

technical compartment
of filtration unit

heat exchanger

pump

electronic
thermostat

suction pipe

discharge pipe

expansion
tank

filtration unit
electrical
control panel

electromagnetic
valve

non-return valve

boiler

3-position valve

Summary of Contents for VUB15

Page 1: ...INSTALLATION MANUAL AND USER S GUIDE UNIVERSAL FILTRATION BLOCKS VUB15 VUB25 and VUB20 50...

Page 2: ...up 14 Connection of universal block s filtration compartment with technical compartment 14 a connection with pump 14 b connection with counter swimming pneumatic button 14 c laying of spotlight elect...

Page 3: ...M DISINFECTION 26 Ideal chlorine level 26 Dosage table 26 14 PRODUCT MAINTENANCE 27 15 HOW TO ELIMINATE SMALL MALFUNCTIONS 27 16 CENTER OF TECHNICAL SUPPORT 28 CERTIFICATE OF WARRANTY 29 Warranty cond...

Page 4: ...the improvement of equipment and also in the case of inaccuracies and misprints All such changes will be introduced into the new edition of user s guide Visit regularly our web page in the Internet w...

Page 5: ...ower supply cable 3x2 5mm2 max 7m compensators decorative side plate console Filtration compartment of universal blocks VUB with without heating includes two prefilter baskets two cups for vacuum clea...

Page 6: ...des one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 spotlights transformer drain outlet multiconductor connection box connecting pipes with sto...

Page 7: ...is 15 kW maximum 59 kW one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 spotlights transformer drain outlet multiconductor connection box conne...

Page 8: ...head H max 19 m Technical compartment includes electric heater of laser type with control box one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 s...

Page 9: ...IPMENT 3 1 Total view and dimensions of universal blocks VU15 VUB25 and VUB20 50 20 650 75 575 595 380 200 65 filtration unit holder skimmer discharge nozzle spotlights 2x75W filtration unit body deco...

Page 10: ...n unit cover spotlights 2x75W discharge nozzle filtration unit body 310 324 76 650 575 filtration unit cover discharge pipe suction pipe spotlight power supply cable filtration unit holder decorative...

Page 11: ...200 filtration unit fixing bolts upper reinforcement technical compartment suction pipe d 50mm back filling drain outlet reinforcing mesh down reinforcement reinforcing mesh swimming pool concrete she...

Page 12: ...tallation of universal blocks technical compartment Preparation of the base for technical compartment Technical compartment should be installed in the location zone 2 VDE 0100 702 For installation of...

Page 13: ...se 16A will be placed at the beginning of panel s power supply circuit before differential protection An all pole disconnection should be provided in the fixed wiring Connection to the electrical netw...

Page 14: ...y the pneumatic hose smoothly not bending it c laying of spotlight electric cable follow instructions from chapter General safety rules Lay a protective pipe of suitable diameter between block s filtr...

Page 15: ...nual 0 Auto 16A 6A On Off 7 ELECTRICAL CONNECTIONS ELECTRIC CONTROL PANEL differencial switch fuse 16A pump s second speed fuse 6A spotlight and pump programmable timer ground terminal strip outgoing...

Page 16: ...rsal blocks Connection of power supplies is made to the top terminals of the differential switch observing polarity Main power supply cable of pump and spotlight transformer is connected to terminals...

Page 17: ...yellow green grounding wire 2 5mm2 cable 7x2 5mm2 to electric control panel brown cable 2x1 0mm2 to spotlight transformer black only for VUB20 50 spotlight pneumatic switch 1 cable 4x2 5mm2 to pump 2...

Page 18: ...lue 5 6 2 1 1 3 cable 4x2 5mm2 to pump 20 50m3 cable 3x1 5mm2 to pump 15 25m3 black only for VUB20 50 ELECTRICAL CONNECTION SCHEME OF HEAT EXCHANGER in universal blocks VU 15 VU 25 and VUB20 50 Make c...

Page 19: ...changer Capacity of the circulating pump Power of the circulating pump 0 72 m3 h 15 kW 1 44 m3 h 29 kW 2 16 m3 h 44 kW 2 88 m3 h 59 kW circulation pump of heating valves circulation pump of heat excha...

Page 20: ...ater Power supply three phase heater neutral phase ground neutral phase ground Electrical control panel neutral 3 phase ground neutral 3 phase ground main power supply main power supply to electric he...

Page 21: ...ous for life If your filtration equipment is not grounded or grounding is done incorrectly there is a risk of corrosion for filtration unit s metal parts because of a difference of potentials The manu...

Page 22: ...nts Backfill a place around technical compartment and pipelines with sand Insert filtration membranes see section Filtration membrane and its installation Switch on filtration unit setting the filtrat...

Page 23: ...unit FILTRATION MEMBRANE REPLACEMENT AND CLEANING ATTENTION Replacement of filtration membranes can be done only after the filtration unit has been disconnected from power supply Disconnect filtratio...

Page 24: ...suction and airing of filtration unit BIG FILTRATION MEMBRANE Big filtration membrane is intended for quick water cleaning a during swimming pool water filling b during first start up of the filtrati...

Page 25: ...If your filtration unit is used in the region with risk of low temperatures we recommend you to make complete conservation of your filtration unit if the water will become frozen some parts of filtrat...

Page 26: ...rine level should be in the borders of 0 8 1 5 g m3 Dosage 1 tablet for 15 20 m3 of water Slow dissolving chlorine tablet ensure 5 7 days chlorination The dosage table The actual dosage could be diffe...

Page 27: ...ch Connect the pneumatic pipeline Triggering of a safety fuse 16 in the electrical control panel of filtration unit Check a safety fuse 16 Triggering of heat protection in the pump s electric motor Sw...

Page 28: ...centre of technical support to the address e mail info vsv group com If you have any questions and proposals or if you want to get information about other VSV Aqua Group products manual and installati...

Page 29: ......

Page 30: ...damage of any origin including but not being limited by this loss of the profit or commercial damage WARRANTY WARRANTY CONDITIONS Guarantee is given only at presence of an authentic guarantee coupon...

Reviews: