21
8 - GROUND CONNECTION MOUNTING
Make the grounding of the filtration equipment following norms of your country.
Connect technical and filtration compartments to the ground with flexible copper wire
with cross-section 10 mm
2
.
ATTENTION!
Absence of grounding is dangerous for life.
If your filtration equipment is not grounded or grounding is done incorrectly, there is a
risk of corrosion for filtration unit’s metal parts because of a difference of potentials.
The manufacturer cannot be considered responsible for possible damage, connected with the absence of
grounding or incorrectly made grounding.
co
pp
er
wi
re
cro
ss
-se
cti
on
10
mm
2
copper wire
cross-section 10mm
2
technical compartment
ground
grounding bolt
filtration compartment