6 – EQUIPMENT MOUNTING 

6.1. Universal blocks mounting 

WATER TOPPING-UP 

Lead a pipe of the water pipeline to filtration block and connect it to the ingoing 

bushing (a thread of 3/8”). Ensure leak resistance of the joint.

  

ATTENTION!

 

The system of automatic water filling is designed for water pressure 

of 4.5 Bars maximum. 

ATTENTION!

 

After the swimming pool is full with water, adjust the regulating screw of the automatic 

water toppin-up device so, that water level will not be lower the upper edge of the skimmer shutter. 

CONNECTION OF BLOCK’S FILTRATION COMPARTMENT AND TECHNICAL COMPARTMENT 

а

) connection with pump 

With the help of pipes d-50mm connect between themselves suction and discharge 

openings as it is specified in the “Universal filtration blocks installation scheme”. 

Pipes are necessary to lay down so that they will form compensators in order to 

prevent pipes damage from temperature expansion. It is necessary to lay down 

pipelines in a depth corresponding to a climatic zone of your region. 

b) connection with pneumatic button of counter-swimming

(for model VUB20/50)

To avoid damage of pneumatic hose during soil back filling, it is necessary to lead it 

in protective pipe of suitable diameter. Lead a pneumatic hose through tightening 

gland in the case of block’s technical compartment. Connect pneumatic hose with pneumatic button in 

the console of the filtration compartment and pneumatic switch in the control box of the pump in the 

technical compartment.  

CAUTION!

 It is necessary to lay the pneumatic hose smoothly, not bending it! 

c) laying of spotlight electric cable

(follow instructions from chapter “General safety rules”) 

Lay a protective pipe of suitable diameter between block’s filtration compartment 

and technical compartment. Lead in it a copper cable 2

х

2,5mm

2

. One end of a cable 

should be in a technical compartment near the spotlight transformer, and the second end near terminals 

in filtration compartment. With the help of terminals connect cable wires in the filtration compartment. 
Connect terminals between themselves. Push the tube on the connected terminals. Heat the tube by air-

heater (blow-drier) so, that it will crimp tightly the terminals. Connect the second end of cable to 

transformer. Tighten cable gland in the technical compartment of filtration block.

 

d) connection with spotlight pneumatic button

To avoid damage of pneumatic hose during soil back filling, it is necessary to lead it 

in protective pipe cover of suitable diameter. Lead a pneumatic hose through 
tightening gland in the case of block’s technical compartments. Connect pneumatic 

hose with pneumatic button in the console of the filtration compartment and pneumatic switch in the 

spotlight transformer.  

CAUTION!

 It is necessary to lay the pneumatic hose smoothly, not bending it!

 

e) connection of technical compartment with drainage

With the help of pipes 50mm connect drain outlet of technical compartment with drainage. 

Create a slope for pipelines to avoid water level rising inside a technical compartment. 

ATTENTION!

 If you connect the drainage pipeline to other drainage systems, carry out the 

joint so that water from other drainage systems will not get into drainage of the technical 
compartment.

 

Summary of Contents for VUB15

Page 1: ...INSTALLATION MANUAL AND USER S GUIDE UNIVERSAL FILTRATION BLOCKS VUB15 VUB25 and VUB20 50...

Page 2: ...up 14 Connection of universal block s filtration compartment with technical compartment 14 a connection with pump 14 b connection with counter swimming pneumatic button 14 c laying of spotlight elect...

Page 3: ...M DISINFECTION 26 Ideal chlorine level 26 Dosage table 26 14 PRODUCT MAINTENANCE 27 15 HOW TO ELIMINATE SMALL MALFUNCTIONS 27 16 CENTER OF TECHNICAL SUPPORT 28 CERTIFICATE OF WARRANTY 29 Warranty cond...

Page 4: ...the improvement of equipment and also in the case of inaccuracies and misprints All such changes will be introduced into the new edition of user s guide Visit regularly our web page in the Internet w...

Page 5: ...ower supply cable 3x2 5mm2 max 7m compensators decorative side plate console Filtration compartment of universal blocks VUB with without heating includes two prefilter baskets two cups for vacuum clea...

Page 6: ...des one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 spotlights transformer drain outlet multiconductor connection box connecting pipes with sto...

Page 7: ...is 15 kW maximum 59 kW one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 spotlights transformer drain outlet multiconductor connection box conne...

Page 8: ...head H max 19 m Technical compartment includes electric heater of laser type with control box one speed pump 220V in models VUB15 and VUB25 or two speeds pump 220V with control box in model VUB20 50 s...

Page 9: ...IPMENT 3 1 Total view and dimensions of universal blocks VU15 VUB25 and VUB20 50 20 650 75 575 595 380 200 65 filtration unit holder skimmer discharge nozzle spotlights 2x75W filtration unit body deco...

Page 10: ...n unit cover spotlights 2x75W discharge nozzle filtration unit body 310 324 76 650 575 filtration unit cover discharge pipe suction pipe spotlight power supply cable filtration unit holder decorative...

Page 11: ...200 filtration unit fixing bolts upper reinforcement technical compartment suction pipe d 50mm back filling drain outlet reinforcing mesh down reinforcement reinforcing mesh swimming pool concrete she...

Page 12: ...tallation of universal blocks technical compartment Preparation of the base for technical compartment Technical compartment should be installed in the location zone 2 VDE 0100 702 For installation of...

Page 13: ...se 16A will be placed at the beginning of panel s power supply circuit before differential protection An all pole disconnection should be provided in the fixed wiring Connection to the electrical netw...

Page 14: ...y the pneumatic hose smoothly not bending it c laying of spotlight electric cable follow instructions from chapter General safety rules Lay a protective pipe of suitable diameter between block s filtr...

Page 15: ...nual 0 Auto 16A 6A On Off 7 ELECTRICAL CONNECTIONS ELECTRIC CONTROL PANEL differencial switch fuse 16A pump s second speed fuse 6A spotlight and pump programmable timer ground terminal strip outgoing...

Page 16: ...rsal blocks Connection of power supplies is made to the top terminals of the differential switch observing polarity Main power supply cable of pump and spotlight transformer is connected to terminals...

Page 17: ...yellow green grounding wire 2 5mm2 cable 7x2 5mm2 to electric control panel brown cable 2x1 0mm2 to spotlight transformer black only for VUB20 50 spotlight pneumatic switch 1 cable 4x2 5mm2 to pump 2...

Page 18: ...lue 5 6 2 1 1 3 cable 4x2 5mm2 to pump 20 50m3 cable 3x1 5mm2 to pump 15 25m3 black only for VUB20 50 ELECTRICAL CONNECTION SCHEME OF HEAT EXCHANGER in universal blocks VU 15 VU 25 and VUB20 50 Make c...

Page 19: ...changer Capacity of the circulating pump Power of the circulating pump 0 72 m3 h 15 kW 1 44 m3 h 29 kW 2 16 m3 h 44 kW 2 88 m3 h 59 kW circulation pump of heating valves circulation pump of heat excha...

Page 20: ...ater Power supply three phase heater neutral phase ground neutral phase ground Electrical control panel neutral 3 phase ground neutral 3 phase ground main power supply main power supply to electric he...

Page 21: ...ous for life If your filtration equipment is not grounded or grounding is done incorrectly there is a risk of corrosion for filtration unit s metal parts because of a difference of potentials The manu...

Page 22: ...nts Backfill a place around technical compartment and pipelines with sand Insert filtration membranes see section Filtration membrane and its installation Switch on filtration unit setting the filtrat...

Page 23: ...unit FILTRATION MEMBRANE REPLACEMENT AND CLEANING ATTENTION Replacement of filtration membranes can be done only after the filtration unit has been disconnected from power supply Disconnect filtratio...

Page 24: ...suction and airing of filtration unit BIG FILTRATION MEMBRANE Big filtration membrane is intended for quick water cleaning a during swimming pool water filling b during first start up of the filtrati...

Page 25: ...If your filtration unit is used in the region with risk of low temperatures we recommend you to make complete conservation of your filtration unit if the water will become frozen some parts of filtrat...

Page 26: ...rine level should be in the borders of 0 8 1 5 g m3 Dosage 1 tablet for 15 20 m3 of water Slow dissolving chlorine tablet ensure 5 7 days chlorination The dosage table The actual dosage could be diffe...

Page 27: ...ch Connect the pneumatic pipeline Triggering of a safety fuse 16 in the electrical control panel of filtration unit Check a safety fuse 16 Triggering of heat protection in the pump s electric motor Sw...

Page 28: ...centre of technical support to the address e mail info vsv group com If you have any questions and proposals or if you want to get information about other VSV Aqua Group products manual and installati...

Page 29: ......

Page 30: ...damage of any origin including but not being limited by this loss of the profit or commercial damage WARRANTY WARRANTY CONDITIONS Guarantee is given only at presence of an authentic guarantee coupon...

Reviews: