S P E C I F I C A T I O N

 

 
 

MEDIA HANDLING   

3½”,  2½”  &  1.8”  hard  drives.  Longitude  & 
perpendicular,  DLT,  S-DLT,  LTO1,  2,  3,  4  &  5; 
3480/3490/3490e, 3590, 9840 & T9940 tape; Ultrium & 
Redwood  SD-3  tape  &  cartridges;  Mammoth  1  &  2, 
8mm,  AIT1  &  2,M2  tape;  DDS  1,  2,  3,  4  &  5,  DD-2  & 
DFT-1 & 2 

 

SLOT DIMENSIONS 

1.1” x 4.3” (28mm x 110mm)

 

 

THROUGHPUT 

200 hard drives in one continuous session or up to 275 
Hard Drives per hour. 

 
 

DUTY CYCLE 

 

 

50% (Dependant on ambient temperature) 

 

CYCLE TIME   

 

8 seconds typical 

 
 

OPERATING VOLTAGE

 

230v (50Hz) or 115v (60Hz) – unit dependant 

 

CURRENT 

 

 

5 amps typical  230 V  50 Hz 

 

 

 

 

 

9 amps typical  115 V  60 Hz 

 
 

TEMPERATURE 

 

5°C (41°F) to 40°C (104°F) 

 
 

HUMIDITY 

 

 

10% to 80% non-condensing 

 

 

 

 

 

 

 

MOUNTING   

 

Free standing table top 

 
 

DIMENSIONS  

 

14.3’’ x 19.2’’ x 14.3’’ (W x H x D) 

 

 

 

 

 

36cm x 48cm x 36cm 

 
 

DIMENSIONS (PACKED) 

19.5’’ x 29.1’’ x 19.5’’ (W x H x D) 

 

 

 

 

 

50cm x 74cm x 50cm 

 

 

 

 

 

 

 

 

 

 

 

 

WEIGHT 

 

 

64 lbs (29kg) 

 
 

PACKED WEIGHT 

 

75 lbs (34kg)

 

 

 

 
 

ENVIRONMENTAL PROTECTION 

Waste electrical products should not be thrown away with household waste.  
Please recycle where facilities exist. 
Check with your local authority or retailer for recycling advice. 

 
 

VS Security Products reserves the right to amend or modify the specifications and design 
criteria applying to these products

 

Summary of Contents for DATAGONE

Page 1: ...TECHNICAL MANUAL Operating and Maintenance Instructions for DATAGONE HARD DRIVE DEGAUSSER ZZ001203 ZZ001204...

Page 2: ...AUSSER IMPORTANT THE POWER ON OFF SWITCH USED ON THIS EQUIPMENT IS NOT AN ISOLATING SWITCH IT IS RECOMMENDED THAT THIS EQUIPMENT SHOULD BE OPERATED FROM A SEPARATE SWITCHED ISOLATOR COPYRIGHT This doc...

Page 3: ...Instructions C O N T E N T S SECTION PAGE List of Contents 3 1 Specification 4 2 Introduction 5 3 Installation 6 4 Control Panel 7 5 Using the Control Panel 7 6 Operation Guide 8 7 Error Messages 9 8...

Page 4: ...t temperature CYCLE TIME 8 seconds typical OPERATING VOLTAGE 230v 50Hz or 115v 60Hz unit dependant CURRENT 5 amps typical 230 V 50 Hz 9 amps typical 115 V 60 Hz TEMPERATURE 5 C 41 F to 40 C 104 F HUMI...

Page 5: ...chamber degausser making operation safe effective and simple for anyone Operators simply post the media into the aperture on one side of the unit and wait for the media to exit the aperture on the op...

Page 6: ...mounted on a pallet Unpack the degausser carefully by disassembling the packing case and inspect it for signs of physical damage If damage is apparent a claim should be filed with the carrier immedia...

Page 7: ...r and will illuminate whenever power is applied The power switch is part of the IEC power connector module mounted on the rear panel 5 3 Reset Button Once you have placed media in the unit the degauss...

Page 8: ...is this end that should be leading when inserted into the degausser This ensures the hard drive is perfectly positioned in the degauss field 4 Once the degauss cycle is complete the hard drive will em...

Page 9: ...on again using the power switch on the rear of the unit 7 1 START UP ERROR EXIT SENSOR TRUE If this message is displayed the Input optical sensor may be contaminated with dust or dirt To resolve this...

Page 10: ...auss chute to detect the media when it enters the unit If the media is dusty or the unit is used in a dusty environment the sensor can become contaminated and not see the media This will result in the...

Page 11: ...ove and clean the sensor The other half of the sensor is on the side of the chute directly opposite the one shown in the Photograph above and should be cleaned in the same way 8 3 Cleaning the Degauss...

Page 12: ...n the rear of the unit this can be manually reset by the user If the unit fails in any way the user should verify the condition of the circuit breaker prior to contacting support 9 SAFETY RECOMMENDATI...

Page 13: ...f 13 Operating Instructions VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot CA 95667 Hampshire GU12 4QP USA UK Tel 44 0 1252 33357...

Reviews: