VS DATAGONE Operating And Maintenance Instructions Manual Download Page 13

________________________________________________________________________________ 

VS SECURITY PRODUCTS

 

ZZ001203 - ZZ001204 

Page 13 of 13 

Operating Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
VS SECURITY PRODUCTS LIMITED 

         VS AND ASSOCIATES 

17 Pegasus Court 

 

                                3160 Texas Hill Road 

North Lane 

 

 

             

         Placerville 

Aldershot 

 

 

 

 

         CA 95667 

Hampshire GU12 4QP 

 

 

         USA 

UK 

 

 

 

 

 

 

 

Tel: 

+44 (0) 1252 333577 

 

         Tel:   530-626-6924 

Fax: 

+44 (0) 1252 333448 

 

         Fax:  530-626-6989 

Email: [email protected] 

         Email: [email protected] 

Summary of Contents for DATAGONE

Page 1: ...TECHNICAL MANUAL Operating and Maintenance Instructions for DATAGONE HARD DRIVE DEGAUSSER ZZ001203 ZZ001204...

Page 2: ...AUSSER IMPORTANT THE POWER ON OFF SWITCH USED ON THIS EQUIPMENT IS NOT AN ISOLATING SWITCH IT IS RECOMMENDED THAT THIS EQUIPMENT SHOULD BE OPERATED FROM A SEPARATE SWITCHED ISOLATOR COPYRIGHT This doc...

Page 3: ...Instructions C O N T E N T S SECTION PAGE List of Contents 3 1 Specification 4 2 Introduction 5 3 Installation 6 4 Control Panel 7 5 Using the Control Panel 7 6 Operation Guide 8 7 Error Messages 9 8...

Page 4: ...t temperature CYCLE TIME 8 seconds typical OPERATING VOLTAGE 230v 50Hz or 115v 60Hz unit dependant CURRENT 5 amps typical 230 V 50 Hz 9 amps typical 115 V 60 Hz TEMPERATURE 5 C 41 F to 40 C 104 F HUMI...

Page 5: ...chamber degausser making operation safe effective and simple for anyone Operators simply post the media into the aperture on one side of the unit and wait for the media to exit the aperture on the op...

Page 6: ...mounted on a pallet Unpack the degausser carefully by disassembling the packing case and inspect it for signs of physical damage If damage is apparent a claim should be filed with the carrier immedia...

Page 7: ...r and will illuminate whenever power is applied The power switch is part of the IEC power connector module mounted on the rear panel 5 3 Reset Button Once you have placed media in the unit the degauss...

Page 8: ...is this end that should be leading when inserted into the degausser This ensures the hard drive is perfectly positioned in the degauss field 4 Once the degauss cycle is complete the hard drive will em...

Page 9: ...on again using the power switch on the rear of the unit 7 1 START UP ERROR EXIT SENSOR TRUE If this message is displayed the Input optical sensor may be contaminated with dust or dirt To resolve this...

Page 10: ...auss chute to detect the media when it enters the unit If the media is dusty or the unit is used in a dusty environment the sensor can become contaminated and not see the media This will result in the...

Page 11: ...ove and clean the sensor The other half of the sensor is on the side of the chute directly opposite the one shown in the Photograph above and should be cleaned in the same way 8 3 Cleaning the Degauss...

Page 12: ...n the rear of the unit this can be manually reset by the user If the unit fails in any way the user should verify the condition of the circuit breaker prior to contacting support 9 SAFETY RECOMMENDATI...

Page 13: ...f 13 Operating Instructions VS SECURITY PRODUCTS LIMITED VS AND ASSOCIATES 17 Pegasus Court 3160 Texas Hill Road North Lane Placerville Aldershot CA 95667 Hampshire GU12 4QP USA UK Tel 44 0 1252 33357...

Reviews: