background image

9050 USER MANUAL

VPC

07/19/2022

For more information visit vpc.com

RETURN TO INDEX

3

INSTALLING 9050 WITH VERTICAL HINGED MOUNTING FRAME 

PART # 310 113 613, 310 104 368

TOOLS REQUIRED

Phillips Head Screwdriver
³/

32  

Allen Wrench

NOTE:

 Due to the weight of the VHMF (approx 15 lbs.) versus the receiver 

(approx. 3 lbs.), it is recommended that the VHMF is attached to the test rack 
first, followed by the receiver to the VHMF. 

INSTALLATION 

1. 

Determine an appropriate location on the rack to mount the VHMF and 
receiver. Keep in mind that the cables connecting to the receiver need to 
be long enough to allow the VHMF to hinge down.  

2. 

Attach the VHMF to the rack in the desired location using the (8) 10-32 x 1” 
mounting screws (

Figure A

). Tighten screws in a cross pattern to ensure 

even torque is applied.  

3. 

Using the 6 receiver mounting holes on the front of the Vertical Hinged 
Mounting Frame (VHMF), attach the receiver with the 10-32 x 1” captive 
screws, lock washers, and hex nuts included with the Receiver (

Figure B

). 

4. 

When not in use, ensure that the receiver handle is closed (upward 
position),  and that the VHMF is in the closed position, secured with the 
two screw knobs located at the top (

Figure C

).

Figure B.

 Receiver attached to VHMF using captive hardware x 6 provided 

with receiver.

SECURED

RECEIVER 

MOUNTING 

HARDWARE X 3 

EACH SIDE

Figure A. 

Back of VHMF with rack mounting screw holes x 8 highlighted. 

Image also available in product drawing for p/n 310104368.

Figure C. VHMF and receiver installed on rack and not in 

use. 

SCREW KNOBS SECURED

RECEIVER HANDLE IN CLOSED 

POSITION 

Summary of Contents for 310 104 368

Page 1: ...ION REGARDING U HEIGHT 9 INSTALLING INSTRUMENT BRACKET 10 INSTALLING KEYBOARD TRAY 12 9050TR PLATFORM REMOVAL REINSTALLATION 13 9050TR HANDLE ROTATION SIDE CHANGE 14 MICROSWITCH REMOVAL INSTALLATION 1...

Page 2: ...ies to forming and enlarging tools It is advisable that power to the interface system be disconnected prior to handling and maintenance Caution should always be used when engaging making sure that all...

Page 3: ...S REQUIRED Phillips Head Screwdriver INSTALLATION INSTRUCTIONS 1 Install clip cage nuts on rack to correlate with mounting holes and captive screws on receiver 2 Place receiver up to clip cage nuts on...

Page 4: ...8 10 32 x 1 mounting screws Figure A Tighten screws in a cross pattern to ensure even torque is applied 3 Using the 6 receiver mounting holes on the front of the Vertical Hinged Mounting Frame VHMF at...

Page 5: ...onnect to instrumentation and allow for slides to fully extend without putting tension on the cables 2 Install both sets of slides using manufacturer s instructions included with slide packaging or on...

Page 6: ...slides to the back of the receiver using the 4 receiver rack mounting screws provided 6 Pull the platform receiver out as far as possible The slides will lock in position Push the blue tabs located o...

Page 7: ...or this length of slide with the inclusion of a longer instrument bracket SLIDE INSTALLATION 1 The height and weight of the 9050 and 9050TR require the use of 2 sets of slides for full support Determi...

Page 8: ...e instrument bracket instructions also in this User Manual 9050 INSTALLATION 1 Install inner slides back into slide kits in the rack 2 Attach the receiver mounting flanges to the inner slide rails on...

Page 9: ...ART 310 104 369 310 104 402 310 104 483 With certain receivers including the 9050 9050TR the slide mechanism protrudes downward slightly into the next U height on both sides of the receiver Please mak...

Page 10: ...groove Push the inner slide in about 6 8 inches and then pull out the right side Slide the track of the mid section over the right side of the inner slide Pull the slide out until the position matches...

Page 11: ...DTRAY PART 310 113 439 MOVEMENT 12 INCH SLIDE 1 2 30 48 KEYBOARD WITH TOUCHPAD KEYBOARD TRAY 12 INCH SLIDES MOUNTING BRACKET RIGHT MOUNTING BRACKET LEFT USB KEYBOARD CONNECTOR RUBBER GROMMET 13 0 330...

Page 12: ...e rack Fully extend the keyboard slides to access the hole locations Figure B 3 Insert the keyboard into the keyboard tray Wrap the plastic strain relief around the cable near the back of the keyboard...

Page 13: ...slides The platform brackets do not need to be removed from the platform for transportation 5 To secure the slides for transport return the slides to the closed position and use zip ties to secure th...

Page 14: ...wrench 2 Remove the handle and reposition in 90 increments Figure A 3 Replace the screw and tighten until the handle is secured tightly SWITCHING HANDLE SIDES 1 Using the 3 32 Allen wrench remove the...

Page 15: ...aining screws using a Phillips screwdriver removing each as they are loosened caution should be used so that the screw s do not fall into the system 4 Carefully remove the microswitch for continuity t...

Page 16: ...ll available options for the 9050 and 9025 ITA TOOLS REQUIRED 3 mm Allen Wrench Phillips Head Screwdriver STANDARD ENCLOSURES 1 To mount ITA frame align frame with enclosure 2 Insert screws and tighte...

Page 17: ...8 N O I T I S O P E L M M O D U L E P O S I T I O N 20 N 5 I T I S O P E L U D O M O M O D U L E P O S I T I O N 1 M D U L E P O S I T I O N 23 O D L E P O S I T I O N 14 O U M 13 N O I T I S O P E L...

Page 18: ...the warranty No continuity upon engagement When replacing an ITA contact the mating contact on the receiver side should also be inspected and replaced if necessary Check wiring and replace if necessa...

Reviews: