- 5 -
Recommended Cable Cross-Sections and Cable Lengths:
VCC 1212-25 Li
VCC 1212-45 Li
cross-section
+/- Pole
cable length IN
II Motor Batt.
Fuse
(A)
cable length
OUT
I Main Batt.
Fuse
(A)
cable length IN
II Motor Batt.
Sich.
(A)
cable length
OUT
I Main Batt.
Fuse
(A)
4 mm²
-
0,5 - 2,0 m
30
-
-
6 mm
2
bis 5,5 m
40
1,5 - 3,5 m
30
-
0,5 - 2,0 m
50
10 mm
2
bis 9,0 m
40
3,0 - 6,5 m
30
bis 5,0 m
80
1,5 - 3,5 m
50
16 mm
2 **
-
-
bis 8,0 m
80
3,0 - 5,0 m
50
VCC 2412-25 Li
VCC 2412-45 Li
cross-section
+/- Pole
cable length IN
II Motor Batt.
Fuse
(A)
cable length
OUT
I Main Batt.
Fuse
(A)
cable length IN
II Motor Batt.
Sich.
(A)
cable length
OUT
I Main Batt.
Fuse
(A)
4 mm²
-
0,5 - 2,0 m
30
-
-
6 mm
2
bis 11,0 m
30
1,5 - 3,5 m
30
-
0,5 - 2,0 m
50
10 mm
2
bis 18,0 m
30
3,0 - 6,5 m
30
bis 10,0 m
40
1,5 - 3,5 m
50
16 mm
2 **
-
-
bis 16,0 m
40
3,0 - 5,0 m
50
* * Insert the cable into the terminal without cable end sleeve
View Front Panel Input