- 14 -
Special Case 1:
Connection Plan for existing Electroblock "EBL",
Only for Types VCC 1212-25 Li and VCC 1212-45 Li:
Imperatively check the mains supply charger of the "EBL" for its suitability for the LiFePO4 battery!
Option:
Voltage display at an EBL of older design
(EBL START In):
After installation of the charging converter in connection with an EBL of older design, it might happen, that the voltage for
the starter battery will not be displayed, if the charging converter had been switched-off.
In this case, the terminal "EBL START In" is to be connected to the voltage of the starter battery.
If possible, the unit should always be installed
as close as possible
to the
board battery I
.
Observe the cable cross-sections, lengths and fuses according to the table on page 5!
Possibly existing cables, which do not have the required cross-sections must be adapted to the
minimum requirements in any case!
Reverse battery (+/-) at the IN II (Start) side will result in serious damage of the unit!