CABLE TIES
9
RELATIVE HUMIDITY THRESHOLD SETTINGS
The desired threshold values for the two relative
humidity sensors can be set during installation. The
values (60, 70, 80, 90%) can be set manually using the
dip switch. Use the possible combinations shown (fig.
7A and 7B).
SENSORS POSITIONING
Remove the lower cover (fig.3 and fig.4). The sensors,
pre-installed on-board the machine, are kept in
position by means of special probe holders fixed to the
scroll (fig. 8 - factory settings). Five adhesive cable ties
are also supplied, to be used to lock the cables to the
sensors to prevent them from entering into the intake
duct and coming into contact with the impeller during
the operating phases (fig. 9). Make sure that the
sensor cables are well secured to the cable ties before
starting up the product.
ENGLISH
8
(Factory)
Configuration A
DIPSWITCH
COMBINAZIONE VALORE SOGLIA RH%
OFF-OFF-OFF-OFF
60%
OFF-ON-OFF-OFF
70%
ON-OFF-OFF-OFF
80%
ON-ON-OFF-OFF
90%
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
1 2 3 4
ON
OFF
7A
7A
7B
7B
A
ON
1 2 3 4
20