44487080
Installation
Instructions
900-4RL Option Board
900-4RL Specifi cations:
Inputs
I1-I4
Dry contacts required (Closed = Active)
Connect control contacts between SC (Signal Common) and any input
Outputs
O1-O4
• Form C contacts rated 30VDC, 3A (Dry) • 12/24VDC, 3A (Wet) when AC powered • 9.6-13.2VDC or
19.2-26.4VDC when battery powered • May be used with PS914 to power EL device at 24VDC, 16A,
300ms • Maximum load cannot exceed power supply ratings or 6A for outputs combined
Board Input Power
Board requires 0.18A max. of power supply output current to operate
Temperature Range
32°-120°F (0°- 49° C)
Compliance
UL 294, ULC-S318, RoHS, & FCC Part 15
Fire Alarm Input
Accepts 900-FA Fire Alarm Board (Optional)
© 2010 Ingersoll-Rand Company
1-877-671-7011
44487080 Rev. 10/10_a
1
INSTALL 4RL BOARD(S) INTO POWER SUPPLY
1a
Review Available 900-4RL
Mounting Locations (Gray)
PS902
PS904
PS914
PS906
1
1
2
2
3
1
1b
Plug 4RL Cable into any
Available Option Connector
1c
Secure Board(s) with Screws
Option 1
Option 2
Option 1
Option 3
Option 2
Option 1
PS902
PS904, 914
PS906
1
To avoid risk of electric shock, turn off AC power to
power supply before installing or wiring option board
DANGER:
!
Refer to installation instructions for compatible supply models - PS902, PS904,
PS906, and PS914.
Note:
For UL listed installations, use
only UL listed locks and strikes